{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/32623"},"canonical_url":"https://search.dev.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/32623","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"A Quasi-Thermal-Mechanical-Biological Model of the Ste-Sophie, QC Landfill","abstract":"A landfill located in Ste-Sophie, QC was instrumented with sensors measuring temperature, oxygen concentration, and settlement. A quasi-thermal-mechanical-biological conceptual model was developed and a corresponding numerical model was set-up in COMSOL Multiphysics to simulate the temperatures within the vertical waste profile. Thermal conductivity was varied with depth and time in the waste profile. An aerobic heat generation model was proposed that related the aerobic heat generation rate to the oxygen concentration measured near the surface. An anaerobic heat generation model presented in the literature was included in the model. The heat generation rate was dependent on waste temperature and the total energy expended. Corresponding field data were collected and the simulated temperatures were in good agreement with measured field temperatures. A heat budget was computed showing that aerobic and anaerobic heat generation accounted for 36% and 64% of total heat generation, respectively, during the filling stages of landfill operation.","abstract_html":"A landfill located in Ste-Sophie, QC was instrumented with sensors measuring temperature, oxygen concentration, and settlement. A quasi-thermal-mechanical-biological conceptual model was developed and a corresponding numerical model was set-up in COMSOL Multiphysics to simulate the temperatures within the vertical waste profile. Thermal conductivity was varied with depth and time in the waste profile. An aerobic heat generation model was proposed that related the aerobic heat generation rate to the oxygen concentration measured near the surface. An anaerobic heat generation model presented in the literature was included in the model. The heat generation rate was dependent on waste temperature and the total energy expended. Corresponding field data were collected and the simulated temperatures were in good agreement with measured field temperatures. A heat budget was computed showing that aerobic and anaerobic heat generation accounted for 36% and 64% of total heat generation, respectively, during the filling stages of landfill operation.","abstract_has_math":false,"creators":["Doyle, James Thomas"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master&apos;s","degree_discipline":"Engineering, Environmental","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-07-24T01:34:32Z","subjects":[],"languages":["en"],"rights":["Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2015-11100"],"render_values":[{"text":"10.22215/etd/2015-11100","href":"https://doi.org/10.22215/etd/2015-11100","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/32623","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Doyle, James Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T17:47:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T17:47:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Environmental"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master&apos;s"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2015-11100"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/32623"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A landfill located in Ste-Sophie, QC was instrumented with sensors measuring temperature, oxygen concentration, and settlement. A quasi-thermal-mechanical-biological conceptual model was developed and a corresponding numerical model was set-up in COMSOL Multiphysics to simulate the temperatures within the vertical waste profile. Thermal conductivity was varied with depth and time in the waste profile. An aerobic heat generation model was proposed that related the aerobic heat generation rate to the oxygen concentration measured near the surface. An anaerobic heat generation model presented in the literature was included in the model. The heat generation rate was dependent on waste temperature and the total energy expended. Corresponding field data were collected and the simulated temperatures were in good agreement with measured field temperatures. A heat budget was computed showing that aerobic and anaerobic heat generation accounted for 36% and 64% of total heat generation, respectively, during the filling stages of landfill operation."]},{"key":"dc:title","label":"Title","values":["A Quasi-Thermal-Mechanical-Biological Model of the Ste-Sophie, QC Landfill"]}]}],"canonical_facts":{"dc:creator":["Doyle, James Thomas"],"dc:date.accessioned":["2025-04-08T17:47:36Z"],"dc:date.available":["2025-04-08T17:47:36Z"],"dc:date.issued":["2015"],"dc:description.abstract":["A landfill located in Ste-Sophie, QC was instrumented with sensors measuring temperature, oxygen concentration, and settlement. A quasi-thermal-mechanical-biological conceptual model was developed and a corresponding numerical model was set-up in COMSOL Multiphysics to simulate the temperatures within the vertical waste profile. Thermal conductivity was varied with depth and time in the waste profile. An aerobic heat generation model was proposed that related the aerobic heat generation rate to the oxygen concentration measured near the surface. An anaerobic heat generation model presented in the literature was included in the model. The heat generation rate was dependent on waste temperature and the total energy expended. Corresponding field data were collected and the simulated temperatures were in good agreement with measured field temperatures. A heat budget was computed showing that aerobic and anaerobic heat generation accounted for 36% and 64% of total heat generation, respectively, during the filling stages of landfill operation."],"dc:identifier.doi":["10.22215/etd/2015-11100"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/32623"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:title":["A Quasi-Thermal-Mechanical-Biological Model of the Ste-Sophie, QC Landfill"],"dc:type":["thesis"],"thesis:degree_discipline":["Engineering, Environmental"],"thesis:degree_level":["Master&apos;s"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-07-24T01:34:32Z"}