Department of Mechanical Engineering

Design, construction and commissioning of an apparatus to perform frequency response diffusivity measurements and high time-resolution ftir spectroscopy

Abstract

dc:description.abstract

The active catalytic sites of zeolites are usually situated within the micropores of the crystals. Since the size of zeolite micropores is of a similar order of magnitude to that of many molecules, the intracrystalline diffusion of reactants and products is often the step that determines both the reaction rate and selectivity. Thus, knowledge of the diffusion rates, and of the diffusional behaviour of molecules within zeolites, is of primary importance in the understanding of these phenomena. While several methods are used to measure diffusivities, most of these have limitations associated with the minimum crystal size that can be used and/or the range of diffusivities that can be measured. Other problems frequently experienced are experimental complexity and the definition of experimental conditions within a range in which the theoretical models are applicable. A powerful method for measuring diffusivities under well-defined conditions is the frequency response method, in which the pressure response to a small volume modulation in a closed system is recorded over a range of frequencies. Models have been developed to determine the diffusivity from such experiments for a variety of circumstances, including non-isothermal conditions and multiple diffusion processes. Fourier transform infra-red (FTIR) spectroscopy can be used to monitor the uptake of sorbate molecules (and hence estimate their diffusivity) in zeolites. In addition, the behaviour of these molecules at the surface, and of the functional groups of the zeolite, can be observed. These observations reveal information about the sorption and diffusional behaviour of the molecules. For a completely reproducible process (e.g. a constant frequency volume modulation), special high time-resolution methods (i.e. rapid- and step-scan) can be used. With these techniques, very rapid molecular processes can be probed.The objective of this study was to design, construct and commission an apparatus capable of measuring diffusivities using the frequency response method, and to integrate it with an FTIR spectrometer to allow the use of standard and high time-resolution spectroscopy.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Mechanical Engineering
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Heydenrych, Hilton Roy
Advisor dc:contributor.advisor
  • Lercher, Johannes A

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/5532
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/5532

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Heydenrych, Hilton Roy. Design, construction and commissioning of an apparatus to perform frequency response diffusivity measurements and high time-resolution ftir spectroscopy. Department of Mechanical Engineering, 2000. http://hdl.handle.net/11427/5532