Back to results

Department of Mechanical Engineering

The development and validation of a geometrically simplified and an accurate finite element model of the wrist joint

Abstract

dc:description.abstract

The injury to the wrist joint resulting from a fall onto the outstretched hand was simulated using two models. The two validated three-dimensional wrist joint models were created using the general purpose finite element software, ABAQUS. The first model, a Geometrically Simplified half symmetry Model (GSM), was created using an approximation of real bone geometry, with material properties that could be varied.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Mechanical Engineering
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Iyer, Yolande-Leigh
Advisor dc:contributor.advisor
  • Nurick, Gerald N

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/5529
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/5529

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Iyer, Yolande-Leigh. The development and validation of a geometrically simplified and an accurate finite element model of the wrist joint. Department of Mechanical Engineering, 2009. http://hdl.handle.net/11427/5529