Back to results

Department of Mechanical Engineering

Thermodynamic analysis and performance evaluation of PTC receiver with external annular fins

Abstract

dc:description.abstract

Since the advent of industrial revolution, the main source of energy has been fossil fuels, and it has resulted in adverse environmental impacts. With the depletion of fossil fuels and greenhouse effect, the utilization of solar energy has attracted increasing attention owing to the distinct advantages, including cleanliness, sustainability, inexhaustibility. This has motivated extensive research and innovation to foster a shift to renewable energies, of which concentrated solar power presents itself as the most promising option. Given the unrivalled abundance of solar energy, the source has a potential to meet a substantial portion of future energy demand. This research investigates the influence of external annular fins on the thermal and thermodynamic performance of parabolic trough collector receiver. The objective is achieved by developing thermal and fluid flow model with geometry of varied fin length and fin numbers in different range of Reynolds number and inlet temperature. The model was implemented in commercial ANSYS Fluent software and validated with existing literature—Forristall (2003) that yielded significant agreement. The results showed that introduction of fins increases thermal efficiency of the receiver. An increase of 2.26 percent for Tin = 350 K, 2.21 percent for Tin = 400 K and 2.22 percent for Tin = 500 K was recorded for varying Reynolds numbers. Also, the thermal efficiency in t = 10 mm was higher than t = 5 mm with values in the range of 88 - 90.5 percent while smooth receiver fell in the range of 84 - 86 percent. Additionally, thermal enhancement factor showed slight improvement. i What's more, exergy efficiency showed an improvement with introduction of fins. It was noted that the enhancement increased the exergy efficiency by 2.44 percent for Re = 5000, 2.30 percent for Re = 10000, and 2.30 percent for Re = 20000. Similarly, entropy generation reduced with fins variations. The entropy generation rate decreases with increasing fin length. The smooth absorber tube has the highest entropy generation rate whereas the absorber tube with largest fin length has the lowest. Heat transfer irreversibility has been found to be dominant at lower turbulence and variation of annular fin length and numbers reduces it. In summary, the introduction of passive enhancement of external annular fins was shown by the results to be thermally and thermodynamically favourable, regardless of the degree of improvement. Therefore, this enhancement technique can be combined with other methods to design a high performing PTC receiver—an endeavour that will contribute to implementation of a stand-alone reliable PTC power plants

Degree

thesis:*
Grantor dc:publisher.institution
Department of Mechanical Engineering
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aketch, Jacob Mator
Advisor dc:contributor.advisor
  • Bello-Ochende, Tunde

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/41208
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/41208

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Aketch, Jacob Mator. Thermodynamic analysis and performance evaluation of PTC receiver with external annular fins. Department of Mechanical Engineering, 2024. http://hdl.handle.net/11427/41208