Back to results

Department of Public Health and Family Medicine

Analysing the technique of blood pressure measurement in primary care: a single pilot study

Abstract

dc:description.abstract

Background: Accurate blood pressure (BP) measurement is essential for the diagnosis and management of hypertension. However, BP measurement technique is often suboptimal in primary healthcare facilities, potentially leading to misdiagnosis and inappropriate management. Objective: To assess the quality of BP measurement technique in a primary healthcare facility in the Western Cape, South Africa, and to identify factors that may affect the accuracy of BP recordings. Methods: A cross-sectional study was conducted using a questionnaire and clinical point of care audit to assess the knowledge, attitude, and skills of healthcare workers involved in BP measurement. Digital BP machines were also audited for calibration and cuff size appropriateness. BP measurements were observed for 102 patients to audit the technique of BP measurement and compared to measurements obtained by the research team using a pre- validated, standardised technique. Results: Knowledge of BP measurement was adequate (>60% on knowledge quiz) amongst 72% of doctors, and inadequate (<60% on knowledge quiz) amongst 81% of nurses. We found widespread use of improper BP cuff sizes and non-calibrated digital BP machines. The use of digital BP machines produced significantly higher systolic BP readings than manual readings (145 vs 141.1; p=0.031), with non-significant differences in diastolic and mean arterial pressures. Conclusion: This study successfully piloted a novel method of assessing BP measurement technique, and identified several factors that could influence measurement outcomes, potentially impacting on clinical care. Recommendations for further research and targeted staff training are suggested.

Degree

thesis:*
Grantor
Department of Public Health and Family Medicine
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Etonu, Joseph Benedict
Advisor dc:contributor.advisor
  • Ras, Tasleem

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/40164
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/40164

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Etonu, Joseph Benedict. Analysing the technique of blood pressure measurement in primary care: a single pilot study. Department of Public Health and Family Medicine, 2023. http://hdl.handle.net/11427/40164