Back to results

Division of General Surgery

A Retrospective Audit Of Biojet® Prostate Fusion Biopsies Amongst Patients Seen In A High-Volume Private Referral Centre In Cape Town Between January 2017 And April 2020

Abstract

dc:description.abstract

Introduction: The field of prostate cancer has seen a dramatic change in its approach to diagnosis, from the advent of PSA in the 1980s to the transrectal ultrasound guided 12 core biopsies with a false negative rate of approximately 30%. Recent advances in this field involve fusing MRI images with real-time ultrasound images to guide the surgeon. The aim of the study was to evaluate the performance of Biojet® prostate fusion biopsy system in a high-volume private referral centre. Methods: Retrospective observational audit of men who presented to a private urology practice in Cape Town for Biojet® prostate fusion biopsy based on clinical suspicion for prostate cancer. Data were collected as per the recommendations of the Standards of Reporting for MRI-targeted Biopsy Studies (START) of the Prostate group and anonymously entered onto a Redcap database. Results: The median age of the patient population was 64 (SD 9.124) years. The median PSA level was 6.5 ng/ml (IQR- 4.7). Most patients (78/135) had a clinical stage of T1c (57%). In the biopsy naïve group, a total of 103 PIRADS lesions were identified. Amongst the PIRADS 3 lesions 15/28 lesions (53%) had a positive cancer diagnosis. Of the PIRADS 4 lesions 37/60 lesions (62%) had a positive cancer diagnosis and in the PIRADS 5 group 13/15 lesions (87%) had a positive cancer diagnosis. 21 of the 42 men (50%) with a previous negative prostate biopsy had a positive cancer diagnosis using the Biojet® prostate fusion biopsy. Conclusion: In this study the Biojet® prostate fusion biopsy performed similar to other international studies however the pickup rate of cancer in those who had a previous negative biopsy was higher than those seen in the other global studies.

Degree

thesis:*
Grantor
Division of General Surgery
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Patel, Bhavinkumar
Advisor dc:contributor.advisor
  • Kaestner, Lisa-Ann

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/39803
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/39803

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Patel, Bhavinkumar. A Retrospective Audit Of Biojet® Prostate Fusion Biopsies Amongst Patients Seen In A High-Volume Private Referral Centre In Cape Town Between January 2017 And April 2020. Division of General Surgery, 2023. http://hdl.handle.net/11427/39803