Back to results

Department of Anaesthesia and Perioperative Medicine

Comparison of a novel low-cost hyperangulated video intubation stylet with the Bonfils fiberscope: a simulated difficult airway manikin study.

Abstract

dc:description.abstract

Introduction Optic stylets are safe, efficient airway tools, with improved intubation success rates compared to direct laryngoscopy. Economic constraints often limit access to costly difficult airway equipment. The Hyperangulated Video Intubation Stylet (HiVIS) is a novel, low-cost, stainless-steel stylet with a Wi-Fi camera connecting to a smartphone. We aim to demonstrate that performance of the HiVIS, as an alternative low-cost device, is non-inferior to the Bonfils. Methods We performed a randomised, cross-over non-inferiority study following institutional and ethics approval (UCT HREC 816/2020). Randomised participants received training (instructional video and practice intubations on a Laerdel airway manikin™) and subsequently intubated a Trucorp Airsim manikin™ simulating a difficult airway with the Bonfils and HiVIS alternately. Our primary outcome was time-to-intubation with a pre-specified non-inferiority margin of 5 seconds. Secondary outcomes were best laryngeal view, airway trauma, and number of attempts. Participants completed a questionnaire regarding device preference and overall satisfaction. Results Thirty doctors participated: 33% interns and 54% medical officers from various specialties. 63% performed ≤1 intubation per week, and 10% had optical stylet experience. Both devices had 100% first-pass intubation success: 10.4 seconds Bonfils versus 11.2 seconds HiVIS (p<0.0001). The mean difference in time-to-intubation was 0.8 seconds (90% CI -0.4; 2.1). All Bonfils intubations had a grade 1 laryngeal view compared to 83% of HiVIS intubations (27% grade 2). The Bonfils had the only incident of airway trauma. Two-thirds of participants preferred HiVIS, with similar user satisfaction scores for both devices. Conclusion The HiVIS is non-inferior to Bonfils in a single attempt difficult airway manikin simulation with predominantly novice, non-anaesthesia users. The HiVIS could be a cost-effective tool for difficult airway management in resource-constrained settings.

Degree

thesis:*
Grantor
Department of Anaesthesia and Perioperative Medicine
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jacobs, Jan
Advisor dc:contributor.advisor
  • Roodt, Francois

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/39513
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/39513

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Jacobs, Jan. Comparison of a novel low-cost hyperangulated video intubation stylet with the Bonfils fiberscope: a simulated difficult airway manikin study.. Department of Anaesthesia and Perioperative Medicine, 2023. http://hdl.handle.net/11427/39513