Back to results

Division of Radiology

Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon

Abstract

dc:description.abstract

Background External beam radiotherapy (EBRT) is an important part of the treatment for prostate cancer. To account for organ motion and set-up error, margins are used in radiotherapy planning. These are essential for the delivery of safe and effective treatment. Aim and Setting To measure prostate motion during the course of EBRT on the HalcyonTM at Groote Schuur Hospital. Using published margin recipes, the minimum clinical target volume (CTV)-planning target volume (PTV) expansion margin was calculated. Patients and Methods Prostate motion was evaluated by comparing prostate position on the planning CT to cone-beam CT (CBCT) scans. Prostate position error in the medio-lateral (ML), antero-posterior (AP) and superoinferior (SI) directions was measured for each CBCT. The systematic (Σ) and random (σ) error of prostate motion was calculated. The minimum CTV-PTV margin was determined. Results The mean position error of the prostate was -0.04mm (95% CI -0.14, 0.10), -0.30mm (95% CI -0.70, 0.15) and -0.40mm (95% CI -0.89, 0.00) in the ML, AP and SI directions, respectively. Using Van Herk's margin formula (2.5Σ +0.7σ), the following minimum CTV-PTV margins for the ML, AP and SI directions were calculated: 1.9mm, 6.9mm and 7.8mm, respectively. Using Stroom's margin formula (2Σ +0.7σ), the following minimum CTV-PTV margins for the ML, AP and SI directions were calculated: 1.6mm, 5.8mm and 6.6mm, respectively. Conclusion Based on prostate motion, our institution's current margins are sufficient. However, further studies are necessary to measure other factors that influence the CTV-PTV margin before considering reducing this margin.

Degree

thesis:*
Grantor
Division of Radiology
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Algar, Marion
Advisor dc:contributor.advisor
  • Punt, Lydia

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/39261
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/39261

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Algar, Marion. Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon. Division of Radiology, 2023. http://hdl.handle.net/11427/39261