Back to results

Blast Impact and Survivability Research Unit

The Design and Construction of a Bulge Testing Device Platform for Human Skin Tissue Applications

Abstract

dc:description.abstract

Limited standard mechanical testing practises and stress-strain data are available for anisotropic human skin tissue in biaxial loading configurations to suitably represent skin in vivo. Inconsistencies in mechanical and physical properties in the literature due to numerous physiological factors have restricted development of biaxial testing equipment in laboratories to ad hoc research solutions having limited modifiability and parametric control. This project aims to develop a biaxial tensile testing device and testing platform which can be used in a research laboratory setting to provide a springboard to expediate mechanical skin tissue testing. The device can be easily reconfigured to accommodate a range of bulge pressures, while being driven via a 10bar compressed air supply. Based on simplified modelling of skin as an elastomer, mechanical and pneumatic resistivecapacitive pressure vessel models are developed. These are used respectively to initially specify a modifiable piston-cylinder bulge testing apparatus, and to design a customisable discrete proportional-integral closed-loop feedback pressurisation rate control system and software control environment. Pressure-time histories were successfully collected and stored on a dedicated computer for silicone sheet samples of 50mm diameter, as a surrogate for skin, that were tested using the platform to maximum pressures of about 200 kPa, at rates set between 2 20 kPa/s. The efficacy of the rate control system was affected by resolution of discrete pressurisation components that were used. The described platform is currently suitable for controlled and measured bulge pressurisation of elastomers. It is recommended to extend facility of the current platform by integrating 3D imaging and measurement technologies, to evaluate deformation of bulged anisotropic skin tissue and map inhomogeneous stress-strain fields for complex tensile stress-strain evaluations.

Degree

thesis:*
Grantor
Blast Impact and Survivability Research Unit
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fischer, Dustin
Advisor dc:contributor.advisor
  • Govender, Reuben

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/32670
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/32670

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Fischer, Dustin. The Design and Construction of a Bulge Testing Device Platform for Human Skin Tissue Applications. Blast Impact and Survivability Research Unit, 2020. http://hdl.handle.net/11427/32670