{"id":{"repo_id":"cape-town","oai_identifier":"oai:open.uct.ac.za:11427/31136"},"canonical_url":"https://search.dev.ndltd.org/etd/cape-town/oai:open.uct.ac.za:11427/31136","repository":{"repo_id":"cape-town","name":"University of Cape Town","base_url":"https://open.uct.ac.za/oai/request"},"display":{"title":"Patient-specific thoracic endovascular aoratic repair (TEVAR)","abstract":"Endovascular aortic repair (EVAR) is a minimally invasive procedure to treat aortic aneurysms. Current off-the-shelf devices may not fit the patient perfectly, potentially increasing the chance of post-operative complications. This project aims to provide proof of concept for rapidly creating inexpensive patient-specific EVAR stent-grafts, conforming to the unique anatomy of the patient. After investigating the range of electrospinning shape capabilities on idealised stent-graft geometries (straight, tapered, elliptical, and curved), CT scans was used to create blood and aortic models of an abdominal aortic aneurysm. The former was used to design a patientspecific stent-graft geometry, 3D print a conductive electrospinning mandrel, and electrospin (290 mm, +18 kV, -3 kV, 5 ml/hr, 5 mm/s, 750 rpm) Polyurethane (PU). Sinusoidal Nitinol reinforcement segments were subsequently incorporated into the graft. Various geometries were successfully spun. Electrospun PU scaffolds had a mean ultimate tensile strength of 7.3 MPa, mean Young’s Modulus of 1.9 MPa, and a mean maximum strain of 571%. Fibre morphology analysis showed a mean orientation index of 0.25 (750 rpm) and 0.35 (1000 rpm), mean fibre diameter of 2.3 µm, and a mean pore size of 7.5 µm; pore size indicates possibility of endothelialisation. Nitinol reinforced patient-specific graft was successfully made and stent-grafts of various stent patterns had radial forces between 1.3 to 5.8 N (comparable to 2.8 N from a commercial example). FEA simulation highlighted various advantages of customised stent-grafts that conform to the anatomy over standard cylindrical devices such as better seal and contact traction. Simulation results (25 mm Ø, cylindrical, electrospun stent-graft) showed close approximations to experimental results; its use for future stent-graft design optimisations is promising. Mock insertion of an electrospun patient-specific stent-graft was performed in a 3D-printed transparent-PLA hollow aortic model with good conformity, albeit subpar visibility without a backlight and inflexibility. Although further improvements can be made to the individual steps, proof of principle was achieved. This process is very promising for the manufacturing of patient-specific devices that could offer better long term outcomes.","abstract_html":"Endovascular aortic repair (EVAR) is a minimally invasive procedure to treat aortic aneurysms. Current off-the-shelf devices may not fit the patient perfectly, potentially increasing the chance of post-operative complications. This project aims to provide proof of concept for rapidly creating inexpensive patient-specific EVAR stent-grafts, conforming to the unique anatomy of the patient. After investigating the range of electrospinning shape capabilities on idealised stent-graft geometries (straight, tapered, elliptical, and curved), CT scans was used to create blood and aortic models of an abdominal aortic aneurysm. The former was used to design a patientspecific stent-graft geometry, 3D print a conductive electrospinning mandrel, and electrospin (290 mm, +18 kV, -3 kV, 5 ml/hr, 5 mm/s, 750 rpm) Polyurethane (PU). Sinusoidal Nitinol reinforcement segments were subsequently incorporated into the graft. Various geometries were successfully spun. Electrospun PU scaffolds had a mean ultimate tensile strength of 7.3 MPa, mean Young’s Modulus of 1.9 MPa, and a mean maximum strain of 571%. Fibre morphology analysis showed a mean orientation index of 0.25 (750 rpm) and 0.35 (1000 rpm), mean fibre diameter of 2.3 µm, and a mean pore size of 7.5 µm; pore size indicates possibility of endothelialisation. Nitinol reinforced patient-specific graft was successfully made and stent-grafts of various stent patterns had radial forces between 1.3 to 5.8 N (comparable to 2.8 N from a commercial example). FEA simulation highlighted various advantages of customised stent-grafts that conform to the anatomy over standard cylindrical devices such as better seal and contact traction. Simulation results (25 mm Ø, cylindrical, electrospun stent-graft) showed close approximations to experimental results; its use for future stent-graft design optimisations is promising. Mock insertion of an electrospun patient-specific stent-graft was performed in a 3D-printed transparent-PLA hollow aortic model with good conformity, albeit subpar visibility without a backlight and inflexibility. Although further improvements can be made to the individual steps, proof of principle was achieved. This process is very promising for the manufacturing of patient-specific devices that could offer better long term outcomes.","abstract_has_math":false,"creators":["Lin, Andrew"],"institution":"Department of Human Biology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Bezuidenhout, Deon","Thierfelder, Nikolaus"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-07-22T22:23:23Z","subjects":["biomedical engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11427/31136","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bezuidenhout, Deon","Thierfelder, Nikolaus"]},{"key":"dc:creator","label":"Author","values":["Lin, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-02-17T11:33:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-02-17T11:33:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Human Biology"]},{"key":"dc:type","label":"Dc Type","values":["Master Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["MSc"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biomedical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11427/31136"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Endovascular aortic repair (EVAR) is a minimally invasive procedure to treat aortic aneurysms. Current off-the-shelf devices may not fit the patient perfectly, potentially increasing the chance of post-operative complications. This project aims to provide proof of concept for rapidly creating inexpensive patient-specific EVAR stent-grafts, conforming to the unique anatomy of the patient. After investigating the range of electrospinning shape capabilities on idealised stent-graft geometries (straight, tapered, elliptical, and curved), CT scans was used to create blood and aortic models of an abdominal aortic aneurysm. The former was used to design a patientspecific stent-graft geometry, 3D print a conductive electrospinning mandrel, and electrospin (290 mm, +18 kV, -3 kV, 5 ml/hr, 5 mm/s, 750 rpm) Polyurethane (PU). Sinusoidal Nitinol reinforcement segments were subsequently incorporated into the graft. Various geometries were successfully spun. Electrospun PU scaffolds had a mean ultimate tensile strength of 7.3 MPa, mean Young’s Modulus of 1.9 MPa, and a mean maximum strain of 571%. Fibre morphology analysis showed a mean orientation index of 0.25 (750 rpm) and 0.35 (1000 rpm), mean fibre diameter of 2.3 µm, and a mean pore size of 7.5 µm; pore size indicates possibility of endothelialisation. Nitinol reinforced patient-specific graft was successfully made and stent-grafts of various stent patterns had radial forces between 1.3 to 5.8 N (comparable to 2.8 N from a commercial example). FEA simulation highlighted various advantages of customised stent-grafts that conform to the anatomy over standard cylindrical devices such as better seal and contact traction. Simulation results (25 mm Ø, cylindrical, electrospun stent-graft) showed close approximations to experimental results; its use for future stent-graft design optimisations is promising. Mock insertion of an electrospun patient-specific stent-graft was performed in a 3D-printed transparent-PLA hollow aortic model with good conformity, albeit subpar visibility without a backlight and inflexibility. Although further improvements can be made to the individual steps, proof of principle was achieved. This process is very promising for the manufacturing of patient-specific devices that could offer better long term outcomes."]},{"key":"dc:title","label":"Title","values":["Patient-specific thoracic endovascular aoratic repair (TEVAR)"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bezuidenhout, Deon","Thierfelder, Nikolaus"],"dc:creator":["Lin, Andrew"],"dc:date.accessioned":["2020-02-17T11:33:04Z"],"dc:date.available":["2020-02-17T11:33:04Z"],"dc:date.issued":["2019"],"dc:description.abstract":["Endovascular aortic repair (EVAR) is a minimally invasive procedure to treat aortic aneurysms. Current off-the-shelf devices may not fit the patient perfectly, potentially increasing the chance of post-operative complications. This project aims to provide proof of concept for rapidly creating inexpensive patient-specific EVAR stent-grafts, conforming to the unique anatomy of the patient. After investigating the range of electrospinning shape capabilities on idealised stent-graft geometries (straight, tapered, elliptical, and curved), CT scans was used to create blood and aortic models of an abdominal aortic aneurysm. The former was used to design a patientspecific stent-graft geometry, 3D print a conductive electrospinning mandrel, and electrospin (290 mm, +18 kV, -3 kV, 5 ml/hr, 5 mm/s, 750 rpm) Polyurethane (PU). Sinusoidal Nitinol reinforcement segments were subsequently incorporated into the graft. Various geometries were successfully spun. Electrospun PU scaffolds had a mean ultimate tensile strength of 7.3 MPa, mean Young’s Modulus of 1.9 MPa, and a mean maximum strain of 571%. Fibre morphology analysis showed a mean orientation index of 0.25 (750 rpm) and 0.35 (1000 rpm), mean fibre diameter of 2.3 µm, and a mean pore size of 7.5 µm; pore size indicates possibility of endothelialisation. Nitinol reinforced patient-specific graft was successfully made and stent-grafts of various stent patterns had radial forces between 1.3 to 5.8 N (comparable to 2.8 N from a commercial example). FEA simulation highlighted various advantages of customised stent-grafts that conform to the anatomy over standard cylindrical devices such as better seal and contact traction. Simulation results (25 mm Ø, cylindrical, electrospun stent-graft) showed close approximations to experimental results; its use for future stent-graft design optimisations is promising. Mock insertion of an electrospun patient-specific stent-graft was performed in a 3D-printed transparent-PLA hollow aortic model with good conformity, albeit subpar visibility without a backlight and inflexibility. Although further improvements can be made to the individual steps, proof of principle was achieved. This process is very promising for the manufacturing of patient-specific devices that could offer better long term outcomes."],"dc:identifier.uri":["http://hdl.handle.net/11427/31136"],"dc:publisher.department":["Department of Human Biology"],"dc:subject":["biomedical engineering"],"dc:title":["Patient-specific thoracic endovascular aoratic repair (TEVAR)"],"dc:type":["Master Thesis"],"dc:type.qualificationlevel":["Masters"],"dc:type.qualificationname":["MSc"]},"updated_at":"2026-07-22T22:23:23Z"}