{"id":{"repo_id":"cape-town","oai_identifier":"oai:open.uct.ac.za:11427/25356"},"canonical_url":"https://search.dev.ndltd.org/etd/cape-town/oai:open.uct.ac.za:11427/25356","repository":{"repo_id":"cape-town","name":"University of Cape Town","base_url":"https://open.uct.ac.za/oai/request"},"display":{"title":"Transforming Doppler tomography to unravel the accretion dynamics in cataclysmic variables","abstract":"Doppler tomography has revolutionised the interpretation of phase-resolved spectra of interacting binaries. The standard technique extracts emission and kinematic information contained in such spectra and projects it onto a two-dimensional velocity coordinate frame. This thesis describes my investigation of constructing Doppler tomograms in 'inside-out' coordinates by reversing the velocity axis. The aim was to determine if the emission distribution in the inside-out tomogram is more intuitive to interpret than the standard tomogram, and if it reveals indiscernible or enhances less discernible details. The inside-out tomogram is constructed by projecting the spectra onto the inside-out coordinate frame with zero velocity transposed to the outer circumference and the maximum velocities to the centre of the tomogram. In addition, this thesis describes a new flux modulation mapping technique applied to the standard and inside-out Doppler tomography of magnetic cataclysmic variables. I developed this technique with the aim to obtain more information from their observed spectra and present it in a useful format. It extracts the flux modulation from consecutive half-phase tomograms and constructs maps of the amplitude and phasing characteristics of the modulation in these systems. My investigation, involving the spectra of non-magnetic and magnetic cataclysmic variables, shows that the inside-out projection redistributes the relative contrast levels in and amongst the emission components. The inside-out projection exposes low-velocity emission details which are overly compacted and enhances high-velocity emission details which are overly tenuous in the standard projection. In addition, the flux modulation mapping technique gives a significant improvement in reproducing the input spectra adding more confidence in the interpretation of the modulation maps. Notable results were obtained for the polars where the blob-like low-velocity emission in their standard tomograms is more exposed in their inside-out tomograms, making it easier to distinguish between the ballistic and magnetic accretion flows that are evident in their trailed spectra. Also, for all the polars investigated the high-velocity magnetic accretion flows not seen in their standard tomograms are revealed in their inside-out tomograms. This extra information is extremely valuable to form a more complete picture of the emission components, broadening our knowledge of the accretion dynamics in these systems.","abstract_html":"Doppler tomography has revolutionised the interpretation of phase-resolved spectra of interacting binaries. The standard technique extracts emission and kinematic information contained in such spectra and projects it onto a two-dimensional velocity coordinate frame. This thesis describes my investigation of constructing Doppler tomograms in &#x27;inside-out&#x27; coordinates by reversing the velocity axis. The aim was to determine if the emission distribution in the inside-out tomogram is more intuitive to interpret than the standard tomogram, and if it reveals indiscernible or enhances less discernible details. The inside-out tomogram is constructed by projecting the spectra onto the inside-out coordinate frame with zero velocity transposed to the outer circumference and the maximum velocities to the centre of the tomogram. In addition, this thesis describes a new flux modulation mapping technique applied to the standard and inside-out Doppler tomography of magnetic cataclysmic variables. I developed this technique with the aim to obtain more information from their observed spectra and present it in a useful format. It extracts the flux modulation from consecutive half-phase tomograms and constructs maps of the amplitude and phasing characteristics of the modulation in these systems. My investigation, involving the spectra of non-magnetic and magnetic cataclysmic variables, shows that the inside-out projection redistributes the relative contrast levels in and amongst the emission components. The inside-out projection exposes low-velocity emission details which are overly compacted and enhances high-velocity emission details which are overly tenuous in the standard projection. In addition, the flux modulation mapping technique gives a significant improvement in reproducing the input spectra adding more confidence in the interpretation of the modulation maps. Notable results were obtained for the polars where the blob-like low-velocity emission in their standard tomograms is more exposed in their inside-out tomograms, making it easier to distinguish between the ballistic and magnetic accretion flows that are evident in their trailed spectra. Also, for all the polars investigated the high-velocity magnetic accretion flows not seen in their standard tomograms are revealed in their inside-out tomograms. This extra information is extremely valuable to form a more complete picture of the emission components, broadening our knowledge of the accretion dynamics in these systems.","abstract_has_math":false,"creators":["Kotze, Enrico Juan"],"institution":"Department of Astronomy","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["McBride, Vanessa A","Potter, Stephen B"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-07-22T22:22:44Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11427/25356","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["McBride, Vanessa A","Potter, Stephen B"]},{"key":"dc:creator","label":"Author","values":["Kotze, Enrico Juan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-09-23T06:38:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-23T06:38:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Cape Town"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11427/25356"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Doppler tomography has revolutionised the interpretation of phase-resolved spectra of interacting binaries. The standard technique extracts emission and kinematic information contained in such spectra and projects it onto a two-dimensional velocity coordinate frame. This thesis describes my investigation of constructing Doppler tomograms in 'inside-out' coordinates by reversing the velocity axis. The aim was to determine if the emission distribution in the inside-out tomogram is more intuitive to interpret than the standard tomogram, and if it reveals indiscernible or enhances less discernible details. The inside-out tomogram is constructed by projecting the spectra onto the inside-out coordinate frame with zero velocity transposed to the outer circumference and the maximum velocities to the centre of the tomogram. In addition, this thesis describes a new flux modulation mapping technique applied to the standard and inside-out Doppler tomography of magnetic cataclysmic variables. I developed this technique with the aim to obtain more information from their observed spectra and present it in a useful format. It extracts the flux modulation from consecutive half-phase tomograms and constructs maps of the amplitude and phasing characteristics of the modulation in these systems. My investigation, involving the spectra of non-magnetic and magnetic cataclysmic variables, shows that the inside-out projection redistributes the relative contrast levels in and amongst the emission components. The inside-out projection exposes low-velocity emission details which are overly compacted and enhances high-velocity emission details which are overly tenuous in the standard projection. In addition, the flux modulation mapping technique gives a significant improvement in reproducing the input spectra adding more confidence in the interpretation of the modulation maps. Notable results were obtained for the polars where the blob-like low-velocity emission in their standard tomograms is more exposed in their inside-out tomograms, making it easier to distinguish between the ballistic and magnetic accretion flows that are evident in their trailed spectra. Also, for all the polars investigated the high-velocity magnetic accretion flows not seen in their standard tomograms are revealed in their inside-out tomograms. This extra information is extremely valuable to form a more complete picture of the emission components, broadening our knowledge of the accretion dynamics in these systems."]},{"key":"dc:title","label":"Title","values":["Transforming Doppler tomography to unravel the accretion dynamics in cataclysmic variables"]}]}],"canonical_facts":{"dc:contributor.advisor":["McBride, Vanessa A","Potter, Stephen B"],"dc:creator":["Kotze, Enrico Juan"],"dc:date.accessioned":["2017-09-23T06:38:09Z"],"dc:date.available":["2017-09-23T06:38:09Z"],"dc:date.issued":["2017"],"dc:description.abstract":["Doppler tomography has revolutionised the interpretation of phase-resolved spectra of interacting binaries. The standard technique extracts emission and kinematic information contained in such spectra and projects it onto a two-dimensional velocity coordinate frame. This thesis describes my investigation of constructing Doppler tomograms in 'inside-out' coordinates by reversing the velocity axis. The aim was to determine if the emission distribution in the inside-out tomogram is more intuitive to interpret than the standard tomogram, and if it reveals indiscernible or enhances less discernible details. The inside-out tomogram is constructed by projecting the spectra onto the inside-out coordinate frame with zero velocity transposed to the outer circumference and the maximum velocities to the centre of the tomogram. In addition, this thesis describes a new flux modulation mapping technique applied to the standard and inside-out Doppler tomography of magnetic cataclysmic variables. I developed this technique with the aim to obtain more information from their observed spectra and present it in a useful format. It extracts the flux modulation from consecutive half-phase tomograms and constructs maps of the amplitude and phasing characteristics of the modulation in these systems. My investigation, involving the spectra of non-magnetic and magnetic cataclysmic variables, shows that the inside-out projection redistributes the relative contrast levels in and amongst the emission components. The inside-out projection exposes low-velocity emission details which are overly compacted and enhances high-velocity emission details which are overly tenuous in the standard projection. In addition, the flux modulation mapping technique gives a significant improvement in reproducing the input spectra adding more confidence in the interpretation of the modulation maps. Notable results were obtained for the polars where the blob-like low-velocity emission in their standard tomograms is more exposed in their inside-out tomograms, making it easier to distinguish between the ballistic and magnetic accretion flows that are evident in their trailed spectra. Also, for all the polars investigated the high-velocity magnetic accretion flows not seen in their standard tomograms are revealed in their inside-out tomograms. This extra information is extremely valuable to form a more complete picture of the emission components, broadening our knowledge of the accretion dynamics in these systems."],"dc:identifier.uri":["http://hdl.handle.net/11427/25356"],"dc:language.iso":["eng"],"dc:publisher.department":["Department of Astronomy"],"dc:publisher.institution":["University of Cape Town"],"dc:title":["Transforming Doppler tomography to unravel the accretion dynamics in cataclysmic variables"],"dc:type":["Doctoral Thesis"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"]},"updated_at":"2026-07-22T22:22:44Z"}