Back to results

Department of Paediatrics and Child Health

A comparison of standard C-reactive protein laboratory measurement to point of care C-reactive protein test in a neonatal intensive care unit setting

Abstract

dc:description.abstract

Background: Laboratory biomarkers are important adjuncts to clinical data in diagnosing neonatal sepsis. Available diagnostic tests often provide results 6 to 48 hours later. A bedside C-reactive protein (CRP) test may be able to exclude or diagnose sepsis within minutes. Objectives: The objectives were to validate the Alere AfinionTM point of care test (POCT) CRP in a tertiary neonatal unit against the gold standard CRP assay in use by the National Health Laboratory service and to determine the difference in time to obtaining a result between the two systems. Methods: A prospective observational study was conducted between February 2015 and June 2015. Neonates who were clinically indicated to undergo CRP testing were simultaneously tested using the POCT and laboratory assays. The sensitivities, specificities and predictive values for the POCT, with the laboratory test as the reference test were determined. The time to results between the two tests was compared. Results: There were 139 measured CRP sample pairs from patients with suspected or proven neonatal sepsis. Using 10 mg/L as the cutoff value for both CRP tests, the sensitivity, specificity, positive predictive value and negative predictive value were 97.4%, 99%, 97.4% and 99% respectively. The area under the receiver operating characteristic curve was 0.99 (p<0.001). The time to point of care result was 4 minutes. Laboratory results were registered at a mean of 4.7 hours but only checked after a mean of 6.8 hours. Conclusions: The POCT CRP and laboratory CRP test have excellent correlation in neonates and may be a useful, quick, reliable method to rationalise antibiotic usage, reduce costs and allow for earlier patient discharge.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Paediatrics and Child Health
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Prince, Kim Didi
Advisor dc:contributor.advisor
  • Joolay, Yaseen

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/22823
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/22823

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Prince, Kim Didi. A comparison of standard C-reactive protein laboratory measurement to point of care C-reactive protein test in a neonatal intensive care unit setting. Department of Paediatrics and Child Health, 2016. http://hdl.handle.net/11427/22823