Chronic Kidney Disease (CKD) is a disease that causes kidney damage, often leading to the patient requiring haemodialysis treatment. Haemodialysis treatment requires a vascular access method, commonly Arteriovenous (AV) fistulae and grafts. These access methods must be regularly assessed to ensure the access remains unblocked and the flow rate is normal. Phase Contrast MRA (PC-MRA) is a versatile Magnetic Resonance Imaging (MRI) modality which is capable of imaging and quantifying blood flow in vivo. It is for this reason that this imaging technique was used to image blood flow in the vasculature of the upper arm of volunteers and haemodialysis patients with either an AV fistula or graft. This imaging technique is capable of producing temporally resolved Three-dimensional (3D) datasets (known as "Four-dimensional (4D)" flow) of blood flow in major vessels. Velocities are phase encoded between -π and π based on the chosen Velocity Encoding Constant (venc). To successfully characterise all velocities in the volume it is necessary to set the venc to be approximately equal to the highest velocity found in the vessel. Any lower venc value will cause phase wrapping, an imaging artefact causing all higher velocities to be wrapped by a multiple of 2 π. However, the increase in sensitivity to high velocities reduces the overall specificity of the velocities, especially for low velocities. Due to the pulsatile nature of blood flow in arterial vessels, a large range of velocities are encountered, while venous flow is more constant but lower than the peak arterial flow value. For this reason and due to the length of the 4D flow scans, 20-30 minutes, it would be preferable to perform one scan at a relatively low venc and correct any phase wrapping during post-processing. In this study, we performed both Two-dimensional (2D) PC-MRA scans at various locations in the upper arm and 4D PC-MRA scaans with similar venc settings. The purpose of the study was to implement and test several methods of phase unwrapping to remove phase wrapping artefacts from affected areas within the PC-MRA datasets.

Degree

thesis:*
Grantor dc:publisher.institution
Division of Biomedical Engineering
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jermy, Stephen
Advisors dc:contributor.advisor
  • Meintjes, Ernesta M
  • Franz, Thomas
  • Auger, Daniel A

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/20492
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/20492

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Jermy, Stephen. 4D flow and displacement sensitive MR imaging of upper arm arterio-venous connections for haemodialysis. Division of Biomedical Engineering, 2016. http://hdl.handle.net/11427/20492