Back to results

Department of Electrical Engineering

Investigation into voltage and angle stability of a hybrid HVAC-HVDC power network

Abstract

dc:description.abstract

This study investigates the power stability problems of HVDC and VSC-HVDC interactions on their hybrid networks with HV AC link, with the intention of bringing out their weaknesses and strengths. The knowledge of this will assist network planners to be informed on ways of improving the efficiency and quality of power systems network. The simulations for this study was done using DIgSILENT Powerfactory software version 14.0.515. This study encapsulates the three major stability problems affecting power systems network, namely, the voltage stability, transient stability and small signal stability. The voltage stability study was conducted using series of load flows at various levels to plot the VP and QV curves, and the results were used to analyze the systems proximity and sensitivity to voltage collapse, as well as the maximum loading point (MPL) of the network. Furthermore, the voltage angle, and terminal voltage responses during a three-phase short circuit disturbance was also used to analyze the voltage stability of the networks. For the transient stability study, several case studies were investigated and their dynamic performances during three-phase short circuit perturbations were analyzed. The small signal stability investigation was done using modal analysis to determine the small signal stability of the three transmission schemes mentioned above. The transient and small signal stability, which are both subsets of rotor angle stability, were further investigated to show the effect of power systems stabilizer (PSS) and automatic voltage regulator (A VR) on rotor angle stability. The results of the analyses show that the HVDC transmission scheme provides the best alternative for bulk power transmission over a long distance. The VSC-HVDC transmission network is suitable for interconnections where the tie with HV AC networks have a low short circuit ratio (SCR). Other conclusions reached with the investigations are explained in chapter ten.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Azimoh, Leonard Chukwuma
Advisors dc:contributor.advisor
  • Folly, Komla A
  • Chowdhury, Shyama Pada

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/17588
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/17588

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Azimoh, Leonard Chukwuma. Investigation into voltage and angle stability of a hybrid HVAC-HVDC power network. Department of Electrical Engineering, 2010. http://hdl.handle.net/11427/17588