Preventing Retained Central Venous Catheter Guidewires

Abstract

dc:description.abstract

Whole central venous catheter (CVC) guidewire retention is an iatrogenic error, with an incidence of 1:3,167, a morbidity of 4-53%, mortality of 4-6% and is a never event. Since 2011, health policy has mandated that all hospitals must implement national safety guidance to prevent this error, emphasising that the never event will be prevented if the guidance has been introduced. Despite this, the error continues to occur, and the reported frequency is rising. The aim of this thesis was to identify a novel approach to prevent this error occurring. A literature search, an analysis of ten years of CVC guidewire retention events nationally, and interviews with ten clinicians who had made the error were conducted. Guidewire retention was found to be an omission error, occurring due to distraction or interruption at a ‘critical point’ in the CVC procedure. Current safety mechanisms were mostly ineffective, and none were 100% effective. Strategies were operator focused interventions and performed after the error had occurred when correction may be difficult. An intraprocedural systems solution that prevents over-insertion or forces early recognition was required. Several solutions were developed and trialled. Finally, the locked procedure pack was deemed the best solution, due to ease of use and implementation, and low cost. A randomised controlled forced error simulation study was used to assess efficacy of the locked procedure pack and prevented CVC guidewire retention in 10/10 versus 2/10 with standard practice (p < 0.001). The locked procedure pack was developed into a clinical product and renamed ‘WireSafe’. When introduced into clinical practice, there were no demonstrable negatives compared to standard practice on procedure duration (10% noninferior margin, p = 0.44), with a significant improvement in sharps safety (100% WireSafe versus 47% standard practice, p = 0.0008) and wide staff acceptability of the device in terms of preventing guidewire retention and improving sharps safety (20/20). Finally, a novel ‘suck out’ suction technique was developed to aid guidewire retrieval. No difference in retrieval techniques were found when the guidewire was retained above skin level, however the ‘suck out’ technique was significantly better when the guidewire was retained below skin level in 9/10 versus 0/10 in withdrawal and 1/10 in clamp and withdrawal (p < 0.001). The WireSafe prevents CVC guidewire retention, protects clinicians from making this error and protects patients from the morbidity and mortality associated with this error. Further work is still required to evaluate the effectiveness of the solution through large scale clinical studies.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Medicine (MD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mariyaselvam, Maryanne
Advisor dc:contributor.advisor
  • Gupta, Arun

Subjects

dc:subject × 5

Rights

dc:rights
Language dc:language
eng

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.17863/CAM.106892
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/365798

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Mariyaselvam, Maryanne. Preventing Retained Central Venous Catheter Guidewires. Doctoral thesis, University of Cambridge, 2023. https://doi.org/10.17863/CAM.106892