Back to results

University of Cambridge

Development of a novel uncovered stent system for the management of complex aortic aneurysms

Abstract

dc:description.abstract

Endovascular aortic repair (EVAR) is a minimally invasive alternative to open surgery for the treatment of aortic aneurysms (AA). However, standard EVAR is not applicable to complex AA with involvement of vital branches, which could be occluded by the endograft. As an emerging technique, the concept of multiple overlapping uncovered stents (MOUS) have been proposed to manage complex lesions. MOUS was used to modulate the flow pattern inside the aneurysm sac, and promote the thrombus formation followed by the aneurysm shrinkage. In this dissertation, we sought to investigate the mechanism of MOUS-induced flow modulation and key factors associated with the success of this novel technique: - The mechanical behaviour of AA was characterised by uniaxial material tests (Chapter 4). A Bayesian framework was proposed for material constants identification. They were found correlated to the microstructure of tissue fibre network and were capable in differentiating tissue types. - Solid-to-solid interaction and one-way fluid-solid interaction (FSI) analysis was performed based on patient-specific computer tomography angiography (Chapters 5&6). Structural stress concentrations were observed within the landing zones, which increased with the number of stents deployed. In the parameter studies (Chapter 6), the overall porosity was identified as the dominant factor of the flow-diverting outcome, while cross-stent structures of MOUS had limited influence. - The pathological effect of structural stress concentration induced by an implanted device was further studied in rabbit models (Chapter 7). The wall structural stress and fluid shear stress were obtained from FSI analysis based on magnetic resonance imaging (MRI), and correlated to plaque characteristics. Both high structural stress and low fluid shear stress were found correlated to plaque initialisation and increased inflammation. Overall, MOUS modulates the blood flow with robust performance under different overlapping patterns. Image-based biomechanical analysis can optimise MOUS design and can contribute to personalised pre-surgery planning.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Shuo
Advisors dc:contributor.advisor
  • Teng, Zhongzhao
  • Gillard, Jonathan

Subjects

dc:subject × 4

Rights

dc:rights
Language dc:language
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.17863/CAM.35679
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/288381

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wang, Shuo. Development of a novel uncovered stent system for the management of complex aortic aneurysms. Doctoral thesis, University of Cambridge, 2019. https://doi.org/10.17863/CAM.35679