Quantitative measurements of temperature using laser-induced thermal grating spectroscopy in reacting and non-reacting flows

Abstract

dc:description.abstract

This thesis is concerned with the development and application of laser induced thermal grating spectroscopy (LITGS) as a tool for thermometry in reacting and non-reacting flows. LITGS signals, which require resonant excitation of an absorbing species in the measurement region to produce a thermal grating, are acquired for systematic measurements of temperature in high pressure flames using OH and NO as target absorbing species in the burned gas. The signal obtained in LITGS measurements appears in the form of a time-based signal with a characteristic frequency proportional to the value or the sound speed of the local medium. With knowledge of the gas composition, the temperature can be derived from the speed of sound measurement. LITGS thermometry using resonant excitation of OH in the burned gas region of in oxygen enriched CH4/O2/N2 and CH4/air laminar flames was performed at elevated pressure (0.5 MPa) for a range of conditions. Measurements were acquired in oxygen enriched flames to provide an environment in which to demonstrate LITGS thermometry under high temperature conditions (up to 2900 K). The primary parameters that influence the quality of LITGS signal were also investigated. The signal contrast, which acts as a marker for the strength of the frequency oscillations, is shown to increase with an increase in the burnt gas density at the measurement point. LITGS employing resonant excitation of NO is also demonstrated for quantitative measurements of temperature in three environments – a static pressure cell at ambient temperature, a non-reacting heated jet at ambient pressure and a laminar premixed CH4/NH3/air flame operating at 0.5 MPa. Flame temperature measurements were acquired at various locations in the burned gas close to a water-cooled stagnation plate, demonstrating the capability of NO-LITGS thermometry for measuring the spatial distribution of temperature in combustion environments. In addition, the parameters that in influence the local temperature rise due to LITGS were also investigated in continuous vapour flows of acetone/air and toluene/air mixtures at atmospheric conditions. Acetone and toluene are commonly targeted species in previous LITGS measurements due to their favourable absorption characteristics. Results indicate that LITGS has the potential to produce accurate and precise measurements of temperature in non-reacting flows, but that the product of the pump intensity at the probe volume and the absorber concentration must remain relatively low to avoid significant localised heating of the measurement region.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lowe, Steven
Advisor dc:contributor.advisor
  • Hochgreb, Simone

Subjects

dc:subject × 35

Rights

dc:rights
Language dc:language
en

Identifiers

dc:identifier.*
Author Identifier
0000-0001-7192-4786
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/277375

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Lowe, Steven. Quantitative measurements of temperature using laser-induced thermal grating spectroscopy in reacting and non-reacting flows. Doctoral thesis, University of Cambridge, 2018. https://doi.org/10.17863/CAM.24670