Back to results

University of Cambridge

A cylindrical specimen holder for electron cryo-tomography

Abstract

dc:description.abstract

The ‘missing wedge’ is a long-standing problem in electron tomography, caused by the use of slab-like flat specimens, which increase in thickness when tilted to high angles. Attempts have been made to reduce the undesirable effects caused by the missing wedge, but the problem remains, particularly for the radiation-sensitive frozen-hydrated specimens used for high resolution imaging. Specimens with cylindrical symmetry offer a way to overcome this problem, since the thickness remains constant at all viewing angles. However, while this has been suggested before, it has never been demonstrated for frozen-hydrated specimens. In this work, I present a way to make cylindrical specimens for electron cryo-tomography, using thin-walled carbon tubes as specimen holders. The tubes are made in a multi-step process, involving carbon deposition on glass micropipette templates and subsequent removal of the glass. Tube diameters are typically a few hundred nanometres, with a wall thickness of 10–20 nm. To make frozen-hydrated specimens, the tubes are filled with an aqueous sample and then plunge-frozen in liquid ethane. Electron images acquired from the tubes have equal quality at all viewing angles, with a tilt range restricted only by the physical limits of the microscope. Tomograms from specimens such as gold particles and liposomes show that the effects of the missing wedge are substantially reduced, with much improved resolution along the electron beam axis. Structural features oriented in all directions are visible in the reconstructions, in marked contrast to tomograms acquired over a more restricted angular range. These results are promising, however some technical challenges remain before this method can be used routinely.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Palmer, Colin Michael

Subjects

dc:subject × 6

Rights

dc:rights
Language dc:language
eng

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.17863/CAM.15950
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/244503

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation