Studies of urban air quality using electrochemical based sensor instruments

Abstract

dc:description.abstract

Poor air quality has been projected to be the world’s top cause of environmental premature mortality by 2050 surpassing poor sanitation and dirty water (IGBP / IGAC press release, 2012 ). One of the major challenges of air quality management is how to adequately quantify both the spatial and temporal variations of pollutants for the purpose of implementing necessary mitigation measures. The work described in this thesis aims to address this problem using novel electrochemical based air quality (AQ) sensors. These instruments are shown to provide cost effective, portable, reliable, indicative measurements for urban air quality assessment as well as for personal exposure studies. Three principal pollutants CO, NO and NO2 are simultaneously measured in each unit of the AQ instrument including temperature / RH measurements as well as GPS (for time and position) and GPRS for data transmission. Laboratory studies showed that the electrochemical sensor nodes can be highly sensitive, showing linear response during calibration tests at ppb level (0-160 ppb). The instrumental detection limits were found to be < 4 ppb (CO and NO) and < 1 ppb for NO2 with fast response time equivalent to t90 < 20 s. Several field studies were carried out involving deployment of both the mobile and static electrochemical sensor nodes. Results from some short-term studies in four different cities including Cambridge (UK), London (UK), Valencia (Spain) and Lagos (Nigeria) are presented. The measurements in these cities represent snapshot of the pollution levels, the stark contrast between the pollution level especially CO (mean mixing ratio of 16 ppm over 3 hrs) in Lagos and the other three cities is a reflection of the poor air quality in that part of the world. Results from long-term AQ monitoring using network of 46 static AQ sensors were used to characterise pollution in different environments ranging from urban to semi-urban and rural locations. By coupling meteorological information (wind measurements) with pollution data, pollution sources, and phenomena like the street canyon effect can be studied. Results from the long-term study also revealed that siting of the current fixed monitoring stations can fail to represent the actual air quality distribution and may therefore be unrepresentative. This work has shown the capability of electrochemical based AQ sensors in complementing the existing fixed site monitors thus demonstrating an emerging measurement paradigm for air quality monitoring and regulation, source attribution and human exposure studies.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Popoola, Olalekan Abdul Muiz

Subjects

dc:subject × 9

Rights

dc:rights
Language dc:language
eng

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.17863/CAM.16288
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/243620

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation