{"id":{"repo_id":"calpoly","oai_identifier":"oai:digitalcommons.calpoly.edu:theses-1775"},"canonical_url":"https://search.dev.ndltd.org/etd/calpoly/oai:digitalcommons.calpoly.edu:theses-1775","repository":{"repo_id":"calpoly","name":"Cal Poly","base_url":"https://digitalcommons.calpoly.edu/do/oai/"},"display":{"title":"Point-Spread Function Assessment of SG-DBR Based Swept Source for OCT Imaging","abstract":"<p> Swept Source Optical Coherence Tomography (SS-OCT) is a medical imaging technique that requires high repetition rate, widely-tunable coherent laser sources. Sampled grating distributed Bragg reflector (SG-DBR) lasers are proven in telecom applications and are expected to fulfill the requirements for SS-OCT at a significantly lower cost than alternative solutions.</p> <p>Constructed entirely on a semiconductor substrate, SG-DBR lasers require four synchronized waveforms to modulate the output wavelength and intensity. Because of this unique tuning mechanism, there are a number of systematic and noise sources that can affect the quality of the OCT point-spread function (PSF). Based on these noise sources, software is developed to simulate the waveforms in an SS-OCT system and determine the factors that limit width of the PSF central peak and the broadband skirts. Design curves are then created to specify the requirements to obtain a given performance. </p> <p> Next, experimental tests are performed on a JDS Uniphase C-band SG-DBR laser to assess its performance limitations. Finally, by comparing theory and experiment, recommendations are made on acceptable systematic and random noise errors induced in the PSF. </p>","abstract_html":"&lt;p&gt; Swept Source Optical Coherence Tomography (SS-OCT) is a medical imaging technique that requires high repetition rate, widely-tunable coherent laser sources. Sampled grating distributed Bragg reflector (SG-DBR) lasers are proven in telecom applications and are expected to fulfill the requirements for SS-OCT at a significantly lower cost than alternative solutions.&lt;/p&gt; &lt;p&gt;Constructed entirely on a semiconductor substrate, SG-DBR lasers require four synchronized waveforms to modulate the output wavelength and intensity. Because of this unique tuning mechanism, there are a number of systematic and noise sources that can affect the quality of the OCT point-spread function (PSF). Based on these noise sources, software is developed to simulate the waveforms in an SS-OCT system and determine the factors that limit width of the PSF central peak and the broadband skirts. Design curves are then created to specify the requirements to obtain a given performance. &lt;/p&gt; &lt;p&gt; Next, experimental tests are performed on a JDS Uniphase C-band SG-DBR laser to assess its performance limitations. Finally, by comparing theory and experiment, recommendations are made on acceptable systematic and random noise errors induced in the PSF. &lt;/p&gt;","abstract_has_math":false,"creators":["Gilbert, David Wilkey"],"institution":null,"degree_name":"MS in Electrical Engineering","degree_level":null,"degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Dennis Derickson"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06-01T07:00:00Z","date_published":"2012-06-01T07:00:00Z","updated_at":"2026-07-24T01:31:17Z","subjects":["Optics","Medicine","Imaging","Simulation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.15368/theses.2012.58"],"render_values":[{"text":"10.15368/theses.2012.58","href":"https://doi.org/10.15368/theses.2012.58","code":true}]}]},"links":{"outbound_url":"https://digitalcommons.calpoly.edu/theses/733","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dennis Derickson"]},{"key":"dc:creator","label":"Author","values":["Gilbert, David Wilkey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-05-30T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS in Electrical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optics","Medicine","Imaging","Simulation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.calpoly.edu/theses/733","10.15368/theses.2012.58"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p> Swept Source Optical Coherence Tomography (SS-OCT) is a medical imaging technique that requires high repetition rate, widely-tunable coherent laser sources. Sampled grating distributed Bragg reflector (SG-DBR) lasers are proven in telecom applications and are expected to fulfill the requirements for SS-OCT at a significantly lower cost than alternative solutions.</p> <p>Constructed entirely on a semiconductor substrate, SG-DBR lasers require four synchronized waveforms to modulate the output wavelength and intensity. Because of this unique tuning mechanism, there are a number of systematic and noise sources that can affect the quality of the OCT point-spread function (PSF). Based on these noise sources, software is developed to simulate the waveforms in an SS-OCT system and determine the factors that limit width of the PSF central peak and the broadband skirts. Design curves are then created to specify the requirements to obtain a given performance. </p> <p> Next, experimental tests are performed on a JDS Uniphase C-band SG-DBR laser to assess its performance limitations. Finally, by comparing theory and experiment, recommendations are made on acceptable systematic and random noise errors induced in the PSF. </p>"]},{"key":"dc:title","label":"Title","values":["Point-Spread Function Assessment of SG-DBR Based Swept Source for OCT Imaging"]}]}],"canonical_facts":{"dc:contributor":["Dennis Derickson"],"dc:creator":["Gilbert, David Wilkey"],"dc:date.available":["2014-05-30T07:00:00Z"],"dc:description.abstract":["<p> Swept Source Optical Coherence Tomography (SS-OCT) is a medical imaging technique that requires high repetition rate, widely-tunable coherent laser sources. Sampled grating distributed Bragg reflector (SG-DBR) lasers are proven in telecom applications and are expected to fulfill the requirements for SS-OCT at a significantly lower cost than alternative solutions.</p> <p>Constructed entirely on a semiconductor substrate, SG-DBR lasers require four synchronized waveforms to modulate the output wavelength and intensity. Because of this unique tuning mechanism, there are a number of systematic and noise sources that can affect the quality of the OCT point-spread function (PSF). Based on these noise sources, software is developed to simulate the waveforms in an SS-OCT system and determine the factors that limit width of the PSF central peak and the broadband skirts. Design curves are then created to specify the requirements to obtain a given performance. </p> <p> Next, experimental tests are performed on a JDS Uniphase C-band SG-DBR laser to assess its performance limitations. Finally, by comparing theory and experiment, recommendations are made on acceptable systematic and random noise errors induced in the PSF. </p>"],"dc:identifier":["https://digitalcommons.calpoly.edu/theses/733","10.15368/theses.2012.58"],"dc:subject":["Optics","Medicine","Imaging","Simulation"],"dc:title":["Point-Spread Function Assessment of SG-DBR Based Swept Source for OCT Imaging"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_name":["MS in Electrical Engineering"]},"updated_at":"2026-07-24T01:31:17Z"}