Back to results

Environmental Design

Life Cycle Optimization of a Zero Carbon Building for CO2e, Energy, and Cost Using Stochastic Controls for an Energy System Integrating a Heat Pump, Solar Air Wall, PV, and a Smart Grid-integrated Thermal Storage (SGTS) Hydronic Battery

Abstract

dc:description.abstract

The life cycle optimization (LCO) of zero carbon buildings (ZC) was examined, using a laneway house built with photovoltaic and solar air wall (SAW) renewable energy collection, air-to-water heat pump, smart grid-integrated thermal storage (SGTS) hydronic battery with an internet-connected stochastic (predictive) control system in subarctic Edmonton, Alberta, Canada. LCO is for global warming potential (GWP), energy, cost, and renewable friendliness. A life cycle assessment (LCA) based methodology (carbon return on investment – CROI) is proposed for design and retrofit decisions on the basis of GWP and cost. Sustainable building rating systems are modelled for their effectiveness in reducing GWP and energy use and are found to reduce life cycle GWP by 18.3% (LEED 2009 certified), 60.7% (PassivHaus 9.30), 96.9% (net zero) and 97.2% (zero carbon) compared to a home built to Alberta Building Code 2014 (base model – BM) over an 80 year life cycle. LCA of the ZC laneway house found a 94.4% reduction in GWP compared to the BM. In the BM, manufacturing, construction, maintenance and end of life phases contributed only 3.6% of life cycle GWP. A modelled HP with stochastic control, SAW and SGTS reduced annual energy consumption by 49.2% compared to a HP only, and by 61.8% compared to resistive heating. Using hourly grid pricing as a proxy of renewable friendliness, modelled optimization under a simulated dynamic pricing system by using hourly historic Alberta electrical pool pricing averaged over each month as a stochastic control mechanism for the HP showed a statistically significant 60.7% to 71.5% energy cost reduction, compared to a thermostatically controlled HP. Preliminary ZC real-life sensor readings are examined.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Grantor dc:publisher.institution
Environmental Design
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stoyke, Godo Albert
Advisor dc:contributor.advisor
  • Assefa, Getachew
Committee members dc:contributor.committeemember
  • Hachem-Vermette, Caroline
  • Layzell, David B.
  • Lee, Tang Gim
  • Blarke, Morten Boje

Subjects

dc:subject × 45

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:ucalgary.scholaris.ca:1880/106444

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Stoyke, Godo Albert. Life Cycle Optimization of a Zero Carbon Building for CO2e, Energy, and Cost Using Stochastic Controls for an Energy System Integrating a Heat Pump, Solar Air Wall, PV, and a Smart Grid-integrated Thermal Storage (SGTS) Hydronic Battery. Environmental Design, 2018. http://hdl.handle.net/1880/106444