{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/2324"},"canonical_url":"https://search.dev.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/2324","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Effect of STATCOM Location on Distance Protection Relay Operation","abstract":"The presence of FACTS in systems has brought up some difficulties to conventional distance protection to meet basic requirements for protection schemes. This dissertation reviews FACTS concepts, and studies shunt-connected STATCOM and its modelling. Based on the dynamic behaviour of STATCOM in a two-machine system, where a distance protection scheme is applied, performance of the two zone distance protection scheme has been evaluated in EMTDC/PSCAD simulation environment for various contingent conditions. This includes different STATCOM installation locations, various STATCOM voltage settings, various fault locations &amp; types. To overcome the mis-operation of the distance relay when the transmission line is shunt compensated with STATCOM, studies on some communication-aided protection schemes, including PUTT, POTT and DCB, are conducted. These pilot protection schemes have been proven to be effective for fast clearance of the faults on the transmission line and meet the requirements for protections, regardless of STATCOM installation locations.","abstract_html":"The presence of FACTS in systems has brought up some difficulties to conventional distance protection to meet basic requirements for protection schemes. This dissertation reviews FACTS concepts, and studies shunt-connected STATCOM and its modelling. Based on the dynamic behaviour of STATCOM in a two-machine system, where a distance protection scheme is applied, performance of the two zone distance protection scheme has been evaluated in EMTDC/PSCAD simulation environment for various contingent conditions. This includes different STATCOM installation locations, various STATCOM voltage settings, various fault locations &amp;amp; types. To overcome the mis-operation of the distance relay when the transmission line is shunt compensated with STATCOM, studies on some communication-aided protection schemes, including PUTT, POTT and DCB, are conducted. These pilot protection schemes have been proven to be effective for fast clearance of the faults on the transmission line and meet the requirements for protections, regardless of STATCOM installation locations.","abstract_has_math":false,"creators":["Sun, Peng"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Nowicki, Ed P.","Malik, Om P."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-06-29","date_published":"2015-06-29","updated_at":"2026-07-24T01:30:20Z","subjects":["Engineering","Engineering--Electronics and Electrical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25810"],"render_values":[{"text":"http://dx.doi.org/10.11575/PRISM/25810","href":"http://dx.doi.org/10.11575/PRISM/25810","code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/11023/2324","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Nowicki, Ed P.","Malik, Om P."]},{"key":"dc:creator","label":"Author","values":["Sun, Peng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-06-29T15:31:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-11-20T08:00:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-06-29"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Engineering--Electronics and Electrical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25810"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2324"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The presence of FACTS in systems has brought up some difficulties to conventional distance protection to meet basic requirements for protection schemes. This dissertation reviews FACTS concepts, and studies shunt-connected STATCOM and its modelling. Based on the dynamic behaviour of STATCOM in a two-machine system, where a distance protection scheme is applied, performance of the two zone distance protection scheme has been evaluated in EMTDC/PSCAD simulation environment for various contingent conditions. This includes different STATCOM installation locations, various STATCOM voltage settings, various fault locations &amp; types. To overcome the mis-operation of the distance relay when the transmission line is shunt compensated with STATCOM, studies on some communication-aided protection schemes, including PUTT, POTT and DCB, are conducted. These pilot protection schemes have been proven to be effective for fast clearance of the faults on the transmission line and meet the requirements for protections, regardless of STATCOM installation locations."]},{"key":"dc:title","label":"Title","values":["Effect of STATCOM Location on Distance Protection Relay Operation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Nowicki, Ed P.","Malik, Om P."],"dc:creator":["Sun, Peng"],"dc:date.accessioned":["2015-06-29T15:31:01Z"],"dc:date.available":["2015-11-20T08:00:32Z"],"dc:date.issued":["2015-06-29"],"dc:description.abstract":["The presence of FACTS in systems has brought up some difficulties to conventional distance protection to meet basic requirements for protection schemes. This dissertation reviews FACTS concepts, and studies shunt-connected STATCOM and its modelling. Based on the dynamic behaviour of STATCOM in a two-machine system, where a distance protection scheme is applied, performance of the two zone distance protection scheme has been evaluated in EMTDC/PSCAD simulation environment for various contingent conditions. This includes different STATCOM installation locations, various STATCOM voltage settings, various fault locations &amp; types. To overcome the mis-operation of the distance relay when the transmission line is shunt compensated with STATCOM, studies on some communication-aided protection schemes, including PUTT, POTT and DCB, are conducted. These pilot protection schemes have been proven to be effective for fast clearance of the faults on the transmission line and meet the requirements for protections, regardless of STATCOM installation locations."],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25810"],"dc:identifier.uri":["http://hdl.handle.net/11023/2324"],"dc:language.iso":["eng"],"dc:publisher.institution":["University of Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering","Engineering--Electronics and Electrical"],"dc:title":["Effect of STATCOM Location on Distance Protection Relay Operation"],"dc:type":["master thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-07-24T01:30:20Z"}