{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-2553"},"canonical_url":"https://search.dev.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-2553","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"Spectroscopic Study of Compressible Mobile Phase and Stationary Phase Behavior in Chromatography","abstract":"Raman spectroscopy, laser-induced fluorescence, and sum-frequency generation (SFG) spectroscopy are used to investigate the behavior of compressible mobile phases and stationary phases under a variety of chromatographic conditions. Efforts to understand and optimize separations employing compressible mobile phases have been limited by a lack of understanding of the mobile phase density gradient. Mobile phase compressibility leads to gradients in linear velocity and solute retention and affects separation speed and efficiency, especially in packed columns. This work describes on-column density measurement of CO2, a common carrier fluid for SFC and SGC, in packed capillary columns using Raman microspectroscopy. On-column detection by laser-induced fluorescence is used to observe the effect of the mobile phase density gradient on separation speed and efficiency, and experimental efficiency is compared to a theoretical model. Additionally, SFG spectroscopy allows for probing the structure of model monomeric and polymeric C18 stationary phases under pressure; this provides a basis for correlating selectivity with pressure-induced structural changes in stationary phase materials. Together, this work provides a more complete understanding of the role of column pressure and fluid compressibility on the speed, efficiency, and selectivity of chemical separations.","abstract_html":"Raman spectroscopy, laser-induced fluorescence, and sum-frequency generation (SFG) spectroscopy are used to investigate the behavior of compressible mobile phases and stationary phases under a variety of chromatographic conditions. Efforts to understand and optimize separations employing compressible mobile phases have been limited by a lack of understanding of the mobile phase density gradient. Mobile phase compressibility leads to gradients in linear velocity and solute retention and affects separation speed and efficiency, especially in packed columns. This work describes on-column density measurement of CO2, a common carrier fluid for SFC and SGC, in packed capillary columns using Raman microspectroscopy. On-column detection by laser-induced fluorescence is used to observe the effect of the mobile phase density gradient on separation speed and efficiency, and experimental efficiency is compared to a theoretical model. Additionally, SFG spectroscopy allows for probing the structure of model monomeric and polymeric C18 stationary phases under pressure; this provides a basis for correlating selectivity with pressure-induced structural changes in stationary phase materials. Together, this work provides a more complete understanding of the role of column pressure and fluid compressibility on the speed, efficiency, and selectivity of chemical separations.","abstract_has_math":false,"creators":["Baker, Lawrence R."],"institution":"Brigham Young University - Provo","degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-07-24T01:29:20Z","subjects":["supercritical fluid chromatography","solvating gas chromatography","compressible mobile phases","packed capillaries","fluid density","column gradients","stationary phase structure","Raman spectroscopy","sum-frequency generation spectroscopy","Biochemistry","Chemistry"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/1554","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Baker, Lawrence R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-07-30T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Brigham Young University - Provo"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["supercritical fluid chromatography","solvating gas chromatography","compressible mobile phases","packed capillaries","fluid density","column gradients","stationary phase structure","Raman spectroscopy","sum-frequency generation spectroscopy","Biochemistry","Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/1554","https://scholarsarchive.byu.edu/context/etd/article/2553/viewcontent/ETD_CISOPTR_1558.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Physical and Mathematical Sciences; Chemistry and Biochemistry"]},{"key":"dc:description.abstract","label":"Abstract","values":["Raman spectroscopy, laser-induced fluorescence, and sum-frequency generation (SFG) spectroscopy are used to investigate the behavior of compressible mobile phases and stationary phases under a variety of chromatographic conditions. Efforts to understand and optimize separations employing compressible mobile phases have been limited by a lack of understanding of the mobile phase density gradient. Mobile phase compressibility leads to gradients in linear velocity and solute retention and affects separation speed and efficiency, especially in packed columns. This work describes on-column density measurement of CO2, a common carrier fluid for SFC and SGC, in packed capillary columns using Raman microspectroscopy. On-column detection by laser-induced fluorescence is used to observe the effect of the mobile phase density gradient on separation speed and efficiency, and experimental efficiency is compared to a theoretical model. Additionally, SFG spectroscopy allows for probing the structure of model monomeric and polymeric C18 stationary phases under pressure; this provides a basis for correlating selectivity with pressure-induced structural changes in stationary phase materials. Together, this work provides a more complete understanding of the role of column pressure and fluid compressibility on the speed, efficiency, and selectivity of chemical separations."]},{"key":"dc:format","label":"Dc Format","values":["application:pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University - Provo"]},{"key":"dc:title","label":"Title","values":["Spectroscopic Study of Compressible Mobile Phase and Stationary Phase Behavior in Chromatography"]}]}],"canonical_facts":{"dc:creator":["Baker, Lawrence R."],"dc:date":["2008-07-30T07:00:00Z"],"dc:description":["Physical and Mathematical Sciences; Chemistry and Biochemistry"],"dc:description.abstract":["Raman spectroscopy, laser-induced fluorescence, and sum-frequency generation (SFG) spectroscopy are used to investigate the behavior of compressible mobile phases and stationary phases under a variety of chromatographic conditions. Efforts to understand and optimize separations employing compressible mobile phases have been limited by a lack of understanding of the mobile phase density gradient. Mobile phase compressibility leads to gradients in linear velocity and solute retention and affects separation speed and efficiency, especially in packed columns. This work describes on-column density measurement of CO2, a common carrier fluid for SFC and SGC, in packed capillary columns using Raman microspectroscopy. On-column detection by laser-induced fluorescence is used to observe the effect of the mobile phase density gradient on separation speed and efficiency, and experimental efficiency is compared to a theoretical model. Additionally, SFG spectroscopy allows for probing the structure of model monomeric and polymeric C18 stationary phases under pressure; this provides a basis for correlating selectivity with pressure-induced structural changes in stationary phase materials. Together, this work provides a more complete understanding of the role of column pressure and fluid compressibility on the speed, efficiency, and selectivity of chemical separations."],"dc:format":["application:pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/1554","https://scholarsarchive.byu.edu/context/etd/article/2553/viewcontent/ETD_CISOPTR_1558.pdf"],"dc:language":["English"],"dc:publisher":["Brigham Young University - Provo"],"dc:source":["Brigham Young University - Provo"],"dc:subject":["supercritical fluid chromatography","solvating gas chromatography","compressible mobile phases","packed capillaries","fluid density","column gradients","stationary phase structure","Raman spectroscopy","sum-frequency generation spectroscopy","Biochemistry","Chemistry"],"dc:title":["Spectroscopic Study of Compressible Mobile Phase and Stationary Phase Behavior in Chromatography"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-07-24T01:29:20Z"}