{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-1350"},"canonical_url":"https://search.dev.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-1350","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"A Framework for an Implantable Wireless Pressure and Volume Sensor Focusing on the Diagnosis and Treatment of Shunt Failure in Hydrocephalus Patients","abstract":"The framework for a permanently implantable wireless compliance sensor was developed and validated using laboratory experiments. The proposed sensor would measure the intracranial pressure and fluid volume in the brain and return this information to a monitoring device. The designed sensor received power remotely from the monitoring device negating the need for an implanted power source. Impedance measurement estimation techniques were suggested, studied and applied to the compliance sensing system. A new impedance measurement technique, accounting for multiple variability in the domain, was developed. An extensive simulation environment was designed and used to develop the laboratory experiments and hardware. The laboratory experiments validated the theory and simulation, proving the concept. Future work was suggested including the next step in the design process and possible research directions for subsequent theses.","abstract_html":"The framework for a permanently implantable wireless compliance sensor was developed and validated using laboratory experiments. The proposed sensor would measure the intracranial pressure and fluid volume in the brain and return this information to a monitoring device. The designed sensor received power remotely from the monitoring device negating the need for an implanted power source. Impedance measurement estimation techniques were suggested, studied and applied to the compliance sensing system. A new impedance measurement technique, accounting for multiple variability in the domain, was developed. An extensive simulation environment was designed and used to develop the laboratory experiments and hardware. The laboratory experiments validated the theory and simulation, proving the concept. Future work was suggested including the next step in the design process and possible research directions for subsequent theses.","abstract_has_math":false,"creators":["Wichern, Donald Monte"],"institution":"Brigham Young University - Provo","degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-07-24T01:27:43Z","subjects":["hydrocephalus","brain","wireless","sensor","impedance","Electrical and Computer Engineering"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/351","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wichern, Donald Monte"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006-01-17T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Brigham Young University - Provo"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["hydrocephalus","brain","wireless","sensor","impedance","Electrical and Computer Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/351","https://scholarsarchive.byu.edu/context/etd/article/1350/viewcontent/ETD_CISOPTR_571.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ira A. Fulton College of Engineering and Technology; Electrical and Computer Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["The framework for a permanently implantable wireless compliance sensor was developed and validated using laboratory experiments. The proposed sensor would measure the intracranial pressure and fluid volume in the brain and return this information to a monitoring device. The designed sensor received power remotely from the monitoring device negating the need for an implanted power source. Impedance measurement estimation techniques were suggested, studied and applied to the compliance sensing system. A new impedance measurement technique, accounting for multiple variability in the domain, was developed. An extensive simulation environment was designed and used to develop the laboratory experiments and hardware. The laboratory experiments validated the theory and simulation, proving the concept. Future work was suggested including the next step in the design process and possible research directions for subsequent theses."]},{"key":"dc:format","label":"Dc Format","values":["application:pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University - Provo"]},{"key":"dc:title","label":"Title","values":["A Framework for an Implantable Wireless Pressure and Volume Sensor Focusing on the Diagnosis and Treatment of Shunt Failure in Hydrocephalus Patients"]}]}],"canonical_facts":{"dc:creator":["Wichern, Donald Monte"],"dc:date":["2006-01-17T08:00:00Z"],"dc:description":["Ira A. Fulton College of Engineering and Technology; Electrical and Computer Engineering"],"dc:description.abstract":["The framework for a permanently implantable wireless compliance sensor was developed and validated using laboratory experiments. The proposed sensor would measure the intracranial pressure and fluid volume in the brain and return this information to a monitoring device. The designed sensor received power remotely from the monitoring device negating the need for an implanted power source. Impedance measurement estimation techniques were suggested, studied and applied to the compliance sensing system. A new impedance measurement technique, accounting for multiple variability in the domain, was developed. An extensive simulation environment was designed and used to develop the laboratory experiments and hardware. The laboratory experiments validated the theory and simulation, proving the concept. Future work was suggested including the next step in the design process and possible research directions for subsequent theses."],"dc:format":["application:pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/351","https://scholarsarchive.byu.edu/context/etd/article/1350/viewcontent/ETD_CISOPTR_571.pdf"],"dc:language":["English"],"dc:publisher":["Brigham Young University - Provo"],"dc:source":["Brigham Young University - Provo"],"dc:subject":["hydrocephalus","brain","wireless","sensor","impedance","Electrical and Computer Engineering"],"dc:title":["A Framework for an Implantable Wireless Pressure and Volume Sensor Focusing on the Diagnosis and Treatment of Shunt Failure in Hydrocephalus Patients"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-07-24T01:27:43Z"}