{"id":{"repo_id":"brock","oai_identifier":"oai:brocku.scholaris.ca:10464/2924"},"canonical_url":"https://search.dev.ndltd.org/etd/brock/oai:brocku.scholaris.ca:10464/2924","repository":{"repo_id":"brock","name":"Brock University","base_url":"https://brocku.scholaris.ca/server/oai/request"},"display":{"title":"The reliability of an isometric test based on constant perception of effort","abstract":"To date there is no documented procedure to extrapolate findings of an isometric nature to a whole body performance setting. The purpose of this study was to quantify the reliability of perceived exertion to control neuromuscular output during an isometric contraction. 21 varsity athletes completed a maximal voluntary contraction and a 2 min constant force contraction at both the start and end of the study. Between pre and post testing all participants completed a 2 min constant perceived exertion contraction once a day for 4 days. Intra-class correlation coefficient (R=O.949) and standard error of measurement (SEM=5.12 Nm) concluded that the isometric contraction was reliable. Limits of agreement demonstrated only moderate initial reliability, yet with smaller limits towards the end of 4 training sessions. In conclusion, athlete&apos;s na&quot;ive to a constant effort isometric contraction will produce reliable and acceptably stable results after 1 familiarization sessions has been completed.","abstract_html":"To date there is no documented procedure to extrapolate findings of an isometric nature to a whole body performance setting. The purpose of this study was to quantify the reliability of perceived exertion to control neuromuscular output during an isometric contraction. 21 varsity athletes completed a maximal voluntary contraction and a 2 min constant force contraction at both the start and end of the study. Between pre and post testing all participants completed a 2 min constant perceived exertion contraction once a day for 4 days. Intra-class correlation coefficient (R=O.949) and standard error of measurement (SEM=5.12 Nm) concluded that the isometric contraction was reliable. Limits of agreement demonstrated only moderate initial reliability, yet with smaller limits towards the end of 4 training sessions. In conclusion, athlete&amp;apos;s na&amp;quot;ive to a constant effort isometric contraction will produce reliable and acceptably stable results after 1 familiarization sessions has been completed.","abstract_has_math":false,"creators":["Kilburn, Shane Michael."],"institution":"Brock University","degree_name":"M.Sc. Applied Health Sciences","degree_level":"Masters","degree_discipline":"Faculty of Applied Health Sciences","degree_department":"Applied Health Sciences Program","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-02-16T15:46:02Z","date_published":"2009-02-16T15:46:02Z","updated_at":"2026-07-24T01:23:09Z","subjects":["Applied kinesiology.","Isometric exercise."],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10464/2924","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Applied Health Sciences Program"]},{"key":"dc:creator","label":"Author","values":["Kilburn, Shane Michael."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-02-16T15:46:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-02-16T15:46:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-02-16T15:46:02Z"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Faculty of Applied Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.Sc. Applied Health Sciences"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Brock University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Applied kinesiology.","Isometric exercise."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10464/2924"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To date there is no documented procedure to extrapolate findings of an isometric nature to a whole body performance setting. The purpose of this study was to quantify the reliability of perceived exertion to control neuromuscular output during an isometric contraction. 21 varsity athletes completed a maximal voluntary contraction and a 2 min constant force contraction at both the start and end of the study. Between pre and post testing all participants completed a 2 min constant perceived exertion contraction once a day for 4 days. Intra-class correlation coefficient (R=O.949) and standard error of measurement (SEM=5.12 Nm) concluded that the isometric contraction was reliable. Limits of agreement demonstrated only moderate initial reliability, yet with smaller limits towards the end of 4 training sessions. In conclusion, athlete&apos;s na&quot;ive to a constant effort isometric contraction will produce reliable and acceptably stable results after 1 familiarization sessions has been completed."]},{"key":"dc:title","label":"Title","values":["The reliability of an isometric test based on constant perception of effort"]}]}],"canonical_facts":{"dc:contributor.department":["Applied Health Sciences Program"],"dc:creator":["Kilburn, Shane Michael."],"dc:date.accessioned":["2010-02-16T15:46:02Z"],"dc:date.available":["2010-02-16T15:46:02Z"],"dc:date.issued":["2009-02-16T15:46:02Z"],"dc:description.abstract":["To date there is no documented procedure to extrapolate findings of an isometric nature to a whole body performance setting. The purpose of this study was to quantify the reliability of perceived exertion to control neuromuscular output during an isometric contraction. 21 varsity athletes completed a maximal voluntary contraction and a 2 min constant force contraction at both the start and end of the study. Between pre and post testing all participants completed a 2 min constant perceived exertion contraction once a day for 4 days. Intra-class correlation coefficient (R=O.949) and standard error of measurement (SEM=5.12 Nm) concluded that the isometric contraction was reliable. Limits of agreement demonstrated only moderate initial reliability, yet with smaller limits towards the end of 4 training sessions. In conclusion, athlete&apos;s na&quot;ive to a constant effort isometric contraction will produce reliable and acceptably stable results after 1 familiarization sessions has been completed."],"dc:identifier.uri":["http://hdl.handle.net/10464/2924"],"dc:language.iso":["eng"],"dc:subject":["Applied kinesiology.","Isometric exercise."],"dc:title":["The reliability of an isometric test based on constant perception of effort"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Faculty of Applied Health Sciences"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.Sc. Applied Health Sciences"],"thesis:institution_name":["Brock University"]},"updated_at":"2026-07-24T01:23:09Z"}