{"id":{"repo_id":"brock","oai_identifier":"oai:brocku.scholaris.ca:10464/1270"},"canonical_url":"https://search.dev.ndltd.org/etd/brock/oai:brocku.scholaris.ca:10464/1270","repository":{"repo_id":"brock","name":"Brock University","base_url":"https://brocku.scholaris.ca/server/oai/request"},"display":{"title":"Flow injection analysis (FIA) determination of lead by hydride generation in banded coral skeletons /","abstract":"A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml&quot;* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h&quot;^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l&apos;l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml&apos;l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.","abstract_html":"A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml&amp;quot;* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h&amp;quot;^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l&amp;apos;l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml&amp;apos;l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.","abstract_has_math":false,"creators":["Tantreamjitmun, Napa."],"institution":"Brock University","degree_name":"M.Sc. Chemistry","degree_level":"Masters","degree_discipline":"Faculty of Mathematics and Science","degree_department":"Department of Chemistry","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997-05-21T13:25:12Z","date_published":"1997-05-21T13:25:12Z","updated_at":"2026-07-24T01:23:05Z","subjects":["Atomic emission spectroscopy.","Hydrides.","Scleractinia.","Lead toxicology."],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10464/1270","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Chemistry"]},{"key":"dc:creator","label":"Author","values":["Tantreamjitmun, Napa."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-05-21T13:25:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-05-21T13:25:12Z"]},{"key":"dc:date.issued","label":"Date","values":["1997-05-21T13:25:12Z"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Faculty of Mathematics and Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.Sc. Chemistry"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Brock University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Atomic emission spectroscopy.","Hydrides.","Scleractinia.","Lead toxicology."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10464/1270"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml&quot;* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h&quot;^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l&apos;l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml&apos;l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand."]},{"key":"dc:title","label":"Title","values":["Flow injection analysis (FIA) determination of lead by hydride generation in banded coral skeletons /"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Chemistry"],"dc:creator":["Tantreamjitmun, Napa."],"dc:date.accessioned":["2009-05-21T13:25:12Z"],"dc:date.available":["2009-05-21T13:25:12Z"],"dc:date.issued":["1997-05-21T13:25:12Z"],"dc:description.abstract":["A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml&quot;* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h&quot;^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l&apos;l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml&apos;l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand."],"dc:identifier.uri":["http://hdl.handle.net/10464/1270"],"dc:language.iso":["eng"],"dc:subject":["Atomic emission spectroscopy.","Hydrides.","Scleractinia.","Lead toxicology."],"dc:title":["Flow injection analysis (FIA) determination of lead by hydride generation in banded coral skeletons /"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Faculty of Mathematics and Science"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.Sc. Chemistry"],"thesis:institution_name":["Brock University"]},"updated_at":"2026-07-24T01:23:05Z"}