Universidade Federal do Rio de Janeiro
Transferência de calor no escoamento bifásico de dois componentes, regime anular, tubo vertical
Abstract
dc:description.abstractAn analytic model for determination of the heat transfer coeficient during the two phase upflow (water + air) in vertical tubes was developped. The design and construction of the equipment is then discussed. The experiments were carried out in one tube, 6mm int and 1500mm of length, which suffered heat fluxes ranging 2 from 0,225 to 0,704 cal/scm². The following ratios water mass flow rate air mass flow rate were used 8, 8.5 and 17. Finally, the experimental results are presented, as well as the values of the heat transfer coeficient determined according to the model.
Degree
thesis:*- Grantor dc:publisher
- Universidade Federal do Rio de Janeiro
- Year dc:date.issued
- 1979
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Brum, Nísio de Carvalho Lobo
- Advisor dc:contributor.advisor
-
- Schmal, Martin
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- Acesso Aberto
- Language dc:language
- por
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/11422/3594
- OAI identifier oai:identifier
- oai:pantheon.ufrj.br:11422/3594