University of Bradford

Design and development of a low cost heart best monitor device using finger photoplethysmography technique :|bcircuit design and fabrication of a non-invasive heart beat monitoring device that employs reflectance and transmission mode photoplethysmography using parallel port interface and microcontroller PIC16F84A.

Abstract

dc:description.abstract

A low cost Heart Beat Monitoring device (HBMD) for detecting heart beat in beats per minute is presented in this thesis. An optical technique called “Photoplethysmography” is utilized by attaching to the base of the finger for monitoring beat to beat pulsation. Two major design issues addressed in this research is to achieve a strong and accurate PPG signal and simultaneously minimizing physiological artefacts and interference. In order to achieve the aim and objectives of the research, this thesis thoroughly explores two new signal conditioning hardware designs. Firstly is the design and fabrication of a low cost reflectance mode PPG heart monitor using parallel port interfacing and secondly are the design and development of a portable transmission mode PPG heart monitor using microcontroller PIC16F84A and PIC16F87. Both PPG heart monitor design is divided into three phases. First is the detection of weak pulses through the fingertip. The PPG signal is then amplified, filtered and digitized by the signal processing unit. Finally the heart rate is calculated, analyzed and displayed on the computer using parallel port interface and on the liquid crystal display using microcontroller PIC16F87. A comprehensive circuit design and analysis work was implemented verified by Proteus VSM circuit simulations and laboratory experiments. Data is presented from the method comparison study in which heart rates measured with the reflectance mode PPG and portable transmission mode PPG heart monitor were compared with those measured with standard techniques on 13 human subjects. Benchmarking tests with approved pulse oximeter and blood pressure monitor Omron M6 reveals that the PPG heart monitor is comparable to those devices in displaying the heart rate. It is also verified through experiments that both PPG heart monitor design fulfill the objectives, including achieving strong and accurate PPG signal, reduction in physiological artefacts and interference and financially low in cost. As the conclusion, the current version of the reflectance mode PPG and portable transmission mode PPG heart monitor successfully measure heart rates fast and reliably in most subjects in different body position. The PPG heart monitor proposed avoid the need to apply electrodes or other sensors in the correct position which directly minimizes the preparation time drastically. This makes the PPG heart monitor more attractive for heart monitoring purpose and its advantage should be explored further.

Degree

thesis:*
Grantor dc:publisher.institution
University of Bradford
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ramli, Nur Ilyani Binti
Advisor dc:contributor.advisor
  • Youseffi, Mansour

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/"><img alt="Creative Commons License" style="border-width:0" src="http://i.creativecommons.org/l/by-nc-nd/3.0/88x31.png" /></a><br />The University of Bradford theses are licenced under a <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/">Creative Commons Licence</a>.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10454/7291
OAI identifier oai:identifier
oai:bradscholars.brad.ac.uk:10454/7291

Chain of custody

source
Harvested from
University of Bradford
Base URL
bradscholars.brad.ac.uk/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Ramli, Nur Ilyani Binti. Design and development of a low cost heart best monitor device using finger photoplethysmography technique :|bcircuit design and fabrication of a non-invasive heart beat monitoring device that employs reflectance and transmission mode photoplethysmography using parallel port interface and microcontroller PIC16F84A.. University of Bradford, 2015. http://hdl.handle.net/10454/7291