Back to results

University of Bradford

Validation of Low Resistance Filters for Gas/Vapour Sampling.

Abstract

dc:description.abstract

Traditional occupational hygiene assessment of occupational exposures to organic gases and vapours rely on low flow (<200 ml/min) NIOSH sorbent tubes. This work investigates 3M charcoal filter media (JK50 and JK40, 3M, Inc.) for collection and analysis of organic vapours across 0.1 ¿ 5 l/min. To enable this work, a custom exposure facility was constructed and validated within which organic analyte gas/vapour concentrations could be introduced at known concentrations while controlling environmental variables such as temperature and humidity and other variables. This facility enabled experiments designed to investigate collection and desorption efficiencies across a range of sample flow rates, temperature and humidity conditions for both NIOSH sorbent tubes (e.g. SKC tube) and 3M charcoal filter media. As a result of the investigations described in this thesis, the following conclusions are drawn. Performance of the 3M charcoal filter media for collection and desorption efficiencies for loading, storage time, humidity and breakthrough at low flow rates (<0.5 l/min) were found comparable to the SKC sorbent tube. It is concluded that 3M charcoal media (JK50 and JK40) are suitable for sampling and analyses of hydrocarbons at flow rates <0.5 l/min. The collection efficiencies of the 3M charcoal filter media were investigated at high flow rates (>0.5l/min) for the same parameters, i.e., loading, temperature and humidity. It is concluded that 3M charcoal filter media can be used with confidence in sampling and analysis of airborne hydrocarbons up to 5 l/min. The Wheeler-Jonas model was found to satisfactorily predict the adsorption kinetics of the 3M charcoal filter media at different loading values of hydrocarbons. It was therefore concluded that the model can be applied to determine the suitable amount of 3M charcoal filter media prior to sampling for a given loading.

Degree

thesis:*
Grantor dc:publisher.institution
University of Bradford
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alarfaj, Ayman M.A.
Advisors dc:contributor.advisor
  • Dennis, John
  • Heron, Carl P.
  • El-Khashab, M.I.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/"><img alt="Creative Commons License" style="border-width:0" src="http://i.creativecommons.org/l/by-nc-nd/3.0/88x31.png" /></a><br />The University of Bradford theses are licenced under a <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/">Creative Commons Licence</a>.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10454/4257
OAI identifier oai:identifier
oai:bradscholars.brad.ac.uk:10454/4257

Chain of custody

source
Harvested from
University of Bradford
Base URL
bradscholars.brad.ac.uk/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Alarfaj, Ayman M.A.. Validation of Low Resistance Filters for Gas/Vapour Sampling.. University of Bradford, 2010. http://hdl.handle.net/10454/4257