Back to results

University of Bradford

Application of Hansen Solubility Parameters and Thermomechanical Techniques to the Prediction of Miscibility of Amorphous Solid Dispersion. Investigating the role of cohesive energy and free volume to predict phase separation kinetics in hot-melt extruded amorphous solid dispersion using dynamic mechanical analyser, shear rheometer and solubility parameters data

Abstract

dc:description.abstract

Hot-melt extruded solid dispersion technique is increasingly employed to improve the solubility of poorly water-soluble drugs. The technique relies on the enhanced solubility of the amorphous form of the drug compared to its crystalline counterpart. These systems however are thermodynamically unstable. This means that the drug crystallises with time. Therefore, efforts to measure the stability of these systems over the life span of the product are crucial. This study focused on investigating the use of Hansen Solubility Parameters to quantify polymer-drug interaction and to predict the stability of solid dispersions. This was achieved through a systematic review of hot-melt extruded solid dispersion literature. The study also investigated the use of a combined mechanical and rheological model to characterise the physicochemical and release behaviour of three solid dispersion immediately after preparation and after storage for one month at 40oC or three months at room temperature. Results revealed that the total solubility parameter |ΔбT| was able to predict the stability of the systems for more than 4 months using a cut-off point of 3 MPa-1 with a negative predictive value of 0.9. This was followed by ΔбD with a cut-off point of 1.5 MPa- 1. Moreover, Dynamic Mechanical Analyser and shear rheometry data were shown to be more sensitive than Differential Scanning Calorimetry, Powder X-Ray Diffraction, Scanning Electron Microscope and Fourier Transform Infrared in detecting crystallisation and the interaction between the drug and the polymer. The Dynamic Mechanical Analyser data were consistent with the dissolution behaviour of the samples when comparing the freshly prepared samples with those after storage. The results highlight the need for a unified characterisation approach and the necessity of verifying the homogeneity of mixing during the extrusion process.

Degree

thesis:*
Grantor dc:publisher.institution
University of Bradford
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mousa, Mohamad A.M.R.
Advisors dc:contributor.advisor
  • Isreb, Mohammad
  • Gough, Tim
  • Timmins, Peter

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/"><img alt="Creative Commons License" style="border-width:0" src="http://i.creativecommons.org/l/by-nc-nd/3.0/88x31.png" /></a><br />The University of Bradford theses are licenced under a <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/">Creative Commons Licence</a>.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10454/19855
OAI identifier oai:identifier
oai:bradscholars.brad.ac.uk:10454/19855

Chain of custody

source
Harvested from
University of Bradford
Base URL
bradscholars.brad.ac.uk/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Mousa, Mohamad A.M.R.. Application of Hansen Solubility Parameters and Thermomechanical Techniques to the Prediction of Miscibility of Amorphous Solid Dispersion. Investigating the role of cohesive energy and free volume to predict phase separation kinetics in hot-melt extruded amorphous solid dispersion using dynamic mechanical analyser, shear rheometer and solubility parameters data. University of Bradford, 2022. http://hdl.handle.net/10454/19855