Back to results

Alma Mater Studiorum - Università di Bologna

Sviluppo di un tomografo multi-energy per lo studio pre-clinico di nuove metodiche diagnostiche finalizzate al riconoscimento precoce della patologia tumorale

Abstract

dc:description

A new multi-energy CT for small animals is being developed at the Physics Department of the University of Bologna, Italy. The system makes use of a set of quasi-monochromatic X-ray beams, with energy tunable in a range from 26 KeV to 72 KeV. These beams are produced by Bragg diffraction on a Highly Oriented Pyrolytic Graphite crystal. With quasi-monochromatic sources it is possible to perform multi-energy investigation in a more effective way, as compared with conventional X-ray tubes. Multi-energy techniques allow extracting physical information from the materials, such as effective atomic number, mass-thickness, density, that can be used to distinguish and quantitatively characterize the irradiated tissues. The aim of the system is the investigation and the development of new pre-clinic methods for the early detection of the tumors in small animals. An innovative technique, the Triple-Energy Radiography with Contrast Medium (TER), has been successfully implemented on our system. TER consist in combining a set of three quasi-monochromatic images of an object, in order to obtain a corresponding set of three single-tissue images, which are the mass-thickness map of three reference materials. TER can be applied to the quantitative mass-thickness-map reconstruction of a contrast medium, because it is able to remove completely the signal due to other tissues (i.e. the structural background noise). The technique is very sensitive to the contrast medium and is insensitive to the superposition of different materials. The method is a good candidate to the early detection of the tumor angiogenesis in mice. In this work we describe the tomographic system, with a particular focus on the quasi-monochromatic source. Moreover the TER method is presented with some preliminary results about small animal imaging.

Degree

thesis:*
Grantor dc:publisher
Alma Mater Studiorum - Università di Bologna
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Masetti, Simone <1970>
Contributors dc:contributor
  • Baldazzi, Giuseppe

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
it

Identifiers

dc:identifier.*
Identifier
urn:nbn:it:unibo-810
OAI identifier oai:identifier
oai:amsdottorato.cib.unibo.it:841

Chain of custody

source
Harvested from
Università di Bologna
Base URL
amsdottorato.unibo.it/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Masetti, Simone <1970>. Sviluppo di un tomografo multi-energy per lo studio pre-clinico di nuove metodiche diagnostiche finalizzate al riconoscimento precoce della patologia tumorale. Alma Mater Studiorum - Università di Bologna, 2008. https://doi.org/10.6092/unibo/amsdottorato/841.