{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:1422"},"canonical_url":"https://search.dev.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:1422","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Evaluation of microwave microscopy for dielectric characterisation","abstract":"A widely used analytical, image charge, model of the SNMM was analysed for the first time in terms of its ability to predict the response of the SNMM to both bulk and thin film dielectrics. For the first time it was shown that the uncertainty in fitting to the model reduces from 10% to 5% when the length of the tip protruding from within the cavity is reduced from 2mm to 1mm. A 5% uncertainty in fitting to the image charge model for the measurement of the relative permittivity of bulk samples is demonstrated.","abstract_html":"A widely used analytical, image charge, model of the SNMM was analysed for the first time in terms of its ability to predict the response of the SNMM to both bulk and thin film dielectrics. For the first time it was shown that the uncertainty in fitting to the model reduces from 10% to 5% when the length of the tip protruding from within the cavity is reduced from 2mm to 1mm. A 5% uncertainty in fitting to the image charge model for the measurement of the relative permittivity of bulk samples is demonstrated.","abstract_has_math":false,"creators":["Barker, Duncan James"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-05","date_published":"2010-05","updated_at":"2026-07-24T01:11:33Z","subjects":["TK Electrical engineering. Electronics Nuclear engineering","TA Engineering (General). Civil engineering (General)","QC Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["epsrc"]},{"key":"dc:creator","label":"Author","values":["Barker, Duncan James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-05"]},{"key":"dc:date.issued","label":"Date","values":["2010-05"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Electronic, Electrical and Systems Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/1422/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TK Electrical engineering. Electronics Nuclear engineering","TA Engineering (General). Civil engineering (General)","QC Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/1422/1/Barker_11_PhD.pdf","http://etheses.bham.ac.uk//id/eprint/1422/2/Decl_IS_Barker_11_PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A widely used analytical, image charge, model of the SNMM was analysed for the first time in terms of its ability to predict the response of the SNMM to both bulk and thin film dielectrics. For the first time it was shown that the uncertainty in fitting to the model reduces from 10% to 5% when the length of the tip protruding from within the cavity is reduced from 2mm to 1mm. A 5% uncertainty in fitting to the image charge model for the measurement of the relative permittivity of bulk samples is demonstrated."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluation of microwave microscopy for dielectric characterisation"]}]}],"canonical_facts":{"dc:contributor.sponsor":["epsrc"],"dc:creator":["Barker, Duncan James"],"dc:date":["2010-05"],"dc:date.issued":["2010-05"],"dc:description.abstract":["A widely used analytical, image charge, model of the SNMM was analysed for the first time in terms of its ability to predict the response of the SNMM to both bulk and thin film dielectrics. For the first time it was shown that the uncertainty in fitting to the model reduces from 10% to 5% when the length of the tip protruding from within the cavity is reduced from 2mm to 1mm. A 5% uncertainty in fitting to the image charge model for the measurement of the relative permittivity of bulk samples is demonstrated."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/1422/1/Barker_11_PhD.pdf","http://etheses.bham.ac.uk//id/eprint/1422/2/Decl_IS_Barker_11_PhD.pdf"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Electronic, Electrical and Systems Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/1422/"],"dc:subject":["TK Electrical engineering. Electronics Nuclear engineering","TA Engineering (General). Civil engineering (General)","QC Physics"],"dc:title":["Evaluation of microwave microscopy for dielectric characterisation"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-07-24T01:11:33Z"}