{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:1094"},"canonical_url":"https://search.dev.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:1094","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Development and validation of a diagnostic tool for occupational asthma based on serial lung function measurements","abstract":"Serial peak expiratory flow measurements (PEF) are recommended as an initial investigation in the confirmation of occupational asthma. Plotting measurements in Oasys gives reproducible results and can be used by non-experts. I report a new analysis, the area between curves (ABC) score, which gives 72% sensitivity and 100% specificity using a cut off of 15 L/min/h. Two-hourly measurements of PEF require 8 work days and 3 rest days for sensitive and specific analysis. Serial PEF records with long periods off work (≥ 4 consecutive days) show improved sensitivity from 73% to 80%, implying that 7 more workers in every 100 would be diagnosed. In a comparison of forced expiratory volume in one second (FEV1) to PEF, PEF was more sensitive to diurnal changes than FEV1, although FEV1 was more reproducible. Exhaled breath nitric oxide (FENO) showed similar ABC scores between those with normal and raised FENO. FENO was significantly correlated to methacholine reactivity. In shift workers, mean ABC scores were increased on morning shifts compared to nights, but the cut off of 15 L/min/h would be applicable across all shift types. The ABC score is a new robust method of confirming occupational asthma requiring shorter records than the Oasys score.","abstract_html":"Serial peak expiratory flow measurements (PEF) are recommended as an initial investigation in the confirmation of occupational asthma. Plotting measurements in Oasys gives reproducible results and can be used by non-experts. I report a new analysis, the area between curves (ABC) score, which gives 72% sensitivity and 100% specificity using a cut off of 15 L/min/h. Two-hourly measurements of PEF require 8 work days and 3 rest days for sensitive and specific analysis. Serial PEF records with long periods off work (≥ 4 consecutive days) show improved sensitivity from 73% to 80%, implying that 7 more workers in every 100 would be diagnosed. In a comparison of forced expiratory volume in one second (FEV1) to PEF, PEF was more sensitive to diurnal changes than FEV1, although FEV1 was more reproducible. Exhaled breath nitric oxide (FENO) showed similar ABC scores between those with normal and raised FENO. FENO was significantly correlated to methacholine reactivity. In shift workers, mean ABC scores were increased on morning shifts compared to nights, but the cut off of 15 L/min/h would be applicable across all shift types. The ABC score is a new robust method of confirming occupational asthma requiring shorter records than the Oasys score.","abstract_has_math":false,"creators":["Moore, Vicky Clare"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-12","date_published":"2010-12","updated_at":"2026-07-24T01:11:23Z","subjects":["RA0421 Public health. Hygiene. Preventive Medicine"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Moore, Vicky Clare"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-12"]},{"key":"dc:date.issued","label":"Date","values":["2010-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Medical & Dental Sciences","School of Health and Population Sciences, Primary Care Clinical Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/1094/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RA0421 Public health. Hygiene. Preventive Medicine"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/1094/3/Moore10PhD.pdf","http://etheses.bham.ac.uk//id/eprint/1094/2/Decl_IS_Moore10PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Serial peak expiratory flow measurements (PEF) are recommended as an initial investigation in the confirmation of occupational asthma. Plotting measurements in Oasys gives reproducible results and can be used by non-experts. I report a new analysis, the area between curves (ABC) score, which gives 72% sensitivity and 100% specificity using a cut off of 15 L/min/h. Two-hourly measurements of PEF require 8 work days and 3 rest days for sensitive and specific analysis. Serial PEF records with long periods off work (≥ 4 consecutive days) show improved sensitivity from 73% to 80%, implying that 7 more workers in every 100 would be diagnosed. In a comparison of forced expiratory volume in one second (FEV1) to PEF, PEF was more sensitive to diurnal changes than FEV1, although FEV1 was more reproducible. Exhaled breath nitric oxide (FENO) showed similar ABC scores between those with normal and raised FENO. FENO was significantly correlated to methacholine reactivity. In shift workers, mean ABC scores were increased on morning shifts compared to nights, but the cut off of 15 L/min/h would be applicable across all shift types. The ABC score is a new robust method of confirming occupational asthma requiring shorter records than the Oasys score."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development and validation of a diagnostic tool for occupational asthma based on serial lung function measurements"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Moore, Vicky Clare"],"dc:date":["2010-12"],"dc:date.issued":["2010-12"],"dc:description.abstract":["Serial peak expiratory flow measurements (PEF) are recommended as an initial investigation in the confirmation of occupational asthma. Plotting measurements in Oasys gives reproducible results and can be used by non-experts. I report a new analysis, the area between curves (ABC) score, which gives 72% sensitivity and 100% specificity using a cut off of 15 L/min/h. Two-hourly measurements of PEF require 8 work days and 3 rest days for sensitive and specific analysis. Serial PEF records with long periods off work (≥ 4 consecutive days) show improved sensitivity from 73% to 80%, implying that 7 more workers in every 100 would be diagnosed. In a comparison of forced expiratory volume in one second (FEV1) to PEF, PEF was more sensitive to diurnal changes than FEV1, although FEV1 was more reproducible. Exhaled breath nitric oxide (FENO) showed similar ABC scores between those with normal and raised FENO. FENO was significantly correlated to methacholine reactivity. In shift workers, mean ABC scores were increased on morning shifts compared to nights, but the cut off of 15 L/min/h would be applicable across all shift types. The ABC score is a new robust method of confirming occupational asthma requiring shorter records than the Oasys score."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/1094/3/Moore10PhD.pdf","http://etheses.bham.ac.uk//id/eprint/1094/2/Decl_IS_Moore10PhD.pdf"],"dc:publisher.department":["College of Medical & Dental Sciences","School of Health and Population Sciences, Primary Care Clinical Sciences"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/1094/"],"dc:subject":["RA0421 Public health. Hygiene. Preventive Medicine"],"dc:title":["Development and validation of a diagnostic tool for occupational asthma based on serial lung function measurements"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-07-24T01:11:23Z"}