Back to results

ResearchSpace@Auckland

Electrophysiological and behavioural measures of central auditory processing in adult cochlear implant users

Abstract

dc:description.abstract

This study aimed to determine the relationship between auditory evoked potential measures, speech perception and frequency discrimination in 12 experienced adult cochlear implant (CI) users and to compare the evoked potential results in the CI subjects to those of a group of age- and gender-matched control subjects with normal hearing. The CI subjects all used the Nucleus CI-22 implant with the SPEAK processing strategy. Subject age range was 27-74 years (mean 50.9 years). All had used their implant for a minimum of one year (range 13-76 months, mean duration of implant use 37.5 months).Duration of profound deafness prior to implantation ranged from 1 - 40 years (mean 15.6 years).Middle latency response (MLR), obligatory N1-P2 cortical potentials, mismatch negativity and P3a auditory evoked potential were recorded. Speech perception was evaluated using tests from "The Minimum Speech Test Battery for Adult Cochlear Implant Users". Frequency discrimination was measured using a two-alternative forced choice procedure, to record difference limens (DL) for a 1000Hz tone. Duration of deafness correlated strongly with speech perception scores with poor scores reflecting greater years of deafness. The most sensitive of all the evoked potential measures was P2 latency, with strong relationships found between P2 and duration of deafness and speech perception scores. Earlier P2 latencies were associated with shorter durations of deafness and higher speech perception scores. In general, mismatch negativity was absent or degraded in CI subjects with poor speech scores. In better implant users mismatch negativity was typically present to both large and small frequency differences and demonstrated characteristic changes of increased latency and decreased area and amplitude for the more difficult discrimination task (as seen in the normal hearing group). Na amplitude of the MLR correlated negatively with duration of deafness, with small amplitudes reflecting greater duration of deafness. Frequency DLs were very variable, and no strong relationships were found between these and the evoked potential or speech perception measures.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Audiology
Grantor dc:publisher
ResearchSpace@Auckland
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kelly, Andrea Susan
Advisors dc:contributor.advisor
  • Dr Suzanne Purdy
  • Dr Peter Thorne

Rights

dc:rights
Statement dc:rights
  • Items in ResearchSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2292/3126
OAI identifier oai:identifier
oai:researchspace.auckland.ac.nz:2292/3126

Chain of custody

source
Harvested from
University of Auckland
Base URL
researchspace.auckland.ac.nz/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Kelly, Andrea Susan. Electrophysiological and behavioural measures of central auditory processing in adult cochlear implant users. Doctoral thesis, ResearchSpace@Auckland, 2001. https://hdl.handle.net/2292/3126