Back to results

Aston University

Artificial Liver Support and Related Systems

Abstract

dc:description.abstract

The primary aim of this research has been the investigation of the use of hydrogel polymers as novel haemoperfusion adsorbents in artificial liver support systems. The work was particularly concerned with the design and development of an in-vitro dynamic evaluation technique to enable the adsorption of a selection of nitrogen-based hepatic toxins on the novel hydrogel polymers and other potential adsorbents to be studied. Initial work was carried out on three types of commercially available adsorbents: activated charcoal/carbon, polymeric neutral resins, and ion exchange resins. The adsorption of ammonia, amino acids, and false neurotransmitter amines on these materials was examined, using both static and dynamic adsorption techniques, and provided information on the effect of factors such as chemical composition, functional groups, particle size, surface area, and physical strength on adsorption. A selection of the adsorbents was encapsulated with hydrogel membranes, and the effect of the polymer coating material on adsorption was evaluated. As a result of the knowledge gained from this study, novel macroporous hydrogel particulates were synthesised (as part of a separate project) and evaluated. Unlike the previously described commercially available adsorbents, these hydrogels were biocompatible. Although their adsorption efficiency was not as great as the best of the commercially available adsorbents, it was adequate for haemoperfusion. The novel macroporous hydrogel particulates appear to have considerable potential as haemoperfusion systems in artificial liver support. An additional area of interest was that of the closely related system of semiconductor-based ammonia sensors. On the basis of the encapsulation studies previously described, hydrogel coatings were selected and used for the encapsulation of the semiconductor-based ammonia sensors. These microchips were then evaluated by Thorn EMI (CRL) UK. These hydrogel-coated semiconductor-based ammonia sensors are potentially useful as in-vivo blood monitors and particularly in artificial liver support systems.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D.
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
Aston University
Year dc:date.issued
1984

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Caesar, Petula A.

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:publications.aston.ac.uk:11720

Chain of custody

source
Harvested from
Aston University
Base URL
publications.aston.ac.uk/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Caesar, Petula A.. Artificial Liver Support and Related Systems. doctoral thesis, Aston University, 1984. https://doi.org/10.48780/publications.aston.ac.uk.00011720