Back to results

The University of Arizona.

Computed Tomographic Imaging Spectrometry

Abstract

dc:description.abstract

A Computed Tomographic Imaging Spectrometer (CTIS) is an imaging spectrometer which can acquire a hyper-spectral data set in a single snapshot (one focal plane array integration time) with no moving parts. A specially designed dispersing element, which separates light from the three-dimensional object cube into a grid of two-dimensional prismatic diffraction orders, is the key element in the instrument. The capabilities of the CTIS instrument can be improved by employing a more optimized grating design.There were two main goals to this research: (1) to design a novel CTIS disperser that will improve CTIS capabilities over the previous 5x5 disperser and (2) to integrate the new disperser into the CTIS and evaluate its performance compared to the 5x5 disperser. Six new disperser ideas were evaluated based on their performance in a number of computer simulations to determine the most optimal dispersion pattern. A new CTIS disperser incorporating a novel radial design pattern was developed and tested. Reconstruction results of various spatial and spectral targets are presented. Capabilities of the new CTIS instrument incorporating the radial grating are compared to the previous instrument employing a 5x5 disperser. While both dispersers perform similarly for point-source objects, the radial grating performs better than the previous disperser for extended sources.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Graduate College
Grantor dc:publisher
The University of Arizona.
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vandervlugt, Corrie Jean
Advisor dc:contributor.advisor
  • Dereniak, Eustace L.
Committee members dc:contributor.committeemember
  • Dallas, William J.
  • Descour, Michael R.
  • Dereniak, Eustace L.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10150/202975
OAI identifier oai:identifier
oai:repository.arizona.edu:10150/202975

Chain of custody

source
Harvested from
University of Arizona
Base URL
repository.arizona.edu/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Vandervlugt, Corrie Jean. Computed Tomographic Imaging Spectrometry. doctoral thesis, The University of Arizona., 2011. http://hdl.handle.net/10150/202975