Back to results

The University of Arizona.

COHERENT DETECTION OF SCATTERED LIGHT BY SUBMICROMETER AEROSOLS.

Abstract

dc:description.abstract

A particle counting instrument, the Coherent Optical Particle Spectrometer (COPS) has been developed for measuring particles in aerosol systems. It optically counts and sizes single particles one at a time as they pass through an optically defined inspection region so particle size distributions can be directly measured. COPS uses the coherent nature of light available in a laser beam to measure the phase shift in the scattered light, which is fundamentally different from previous intensity based techniques. The Van-Cittert-Zernike theorem shows that scattered light from small particles will be coherent if viewed upon at the focal point of a gathering lens. Optical homodyne detection can then be used to measure the extent of the phase shift due to the particle. Scattering mechanisms can relate the phase shift to particle diameter so particle size can be determined. An optical inspection region is given by the resolution limited blur spot diameter and depth of focus of the gathering lens. Particles scattering outside this zone will not contribute to measured phase signals. Calculations show that COPS can count in concentrations of 10('9) particles per cubic centimeter with 5% coincidence error. Mie scattering calculations, coupled with homodyne theory, predict a minimum detectable particle diameter ranging from 0.03 to 0.3 micrometers, depending on optical configuration. Theory shows that small, strongly absorbing particles impart a much larger phase shift than refractive particles so a lower detection limit is predicted for particles such as soot and silicon. Particles above one micrometer show classic resonance typical of Mie calculations. An experimental COPS system verified the predicted results from the model. Resolution of particle size ranged from 25 to 60 percent of particle diameter. Preliminary experiments showed that COPS has in situ sampling possibilities and will work for liquid systems as well. Coherent detection of scattered light shows promise for in situ measurement of submicrometer aerosols in high particle laden streams with maximum sensitivity for strongly absorbing particles.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemical Engineering
Grantor dc:publisher
The University of Arizona.
Year dc:date.issued
1983

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • PETTIT, DONALD ROY.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10150/186546
OAI identifier oai:identifier
oai:repository.arizona.edu:10150/186546

Chain of custody

source
Harvested from
University of Arizona
Base URL
repository.arizona.edu/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

PETTIT, DONALD ROY.. COHERENT DETECTION OF SCATTERED LIGHT BY SUBMICROMETER AEROSOLS.. doctoral thesis, The University of Arizona., 1983. http://hdl.handle.net/10150/186546