{"id":{"repo_id":"aachen","oai_identifier":"oai:publications.rwth-aachen.de:51118"},"canonical_url":"https://search.dev.ndltd.org/etd/aachen/oai:publications.rwth-aachen.de:51118","repository":{"repo_id":"aachen","name":"RWTH Aachen University","base_url":"https://publications.rwth-aachen.de/oai2d"},"display":{"title":"Untersuchung zur Veränderung der mechanischen Festigkeit von In-Ceram-Kronen in Abhängigkeit von der Lagerung in Kunstspeichel","abstract":"This PhD Thesis is to prove if In-Ceram® (Registered Trademak by Vita) implemented in Incisivi/Caninicrowns provides sufficient strength when being exposed to artificial salivar, to be applied like VMK in the field of aesthetical front-tooth dental treatment. Our trials have been based on \"Normkronentest\" by Voss, to provide a scenario being compatible with findings resulting from rather traditional Verblendkronen applications. No significant influence of exposure to Fusajama salivar on the fracture strength could be stated. Also,comparisons of Incisivi/Canini parameters did not lead to significant differences. To gain a test body,we chose slurry lamination instead of an injection technique, to allow a higher degree of practical relevance. According to specifications by Vita,both an Incisivus and a Caninus were designed with rounded layers in a four-degree convergence angle. To assure a perfect fitting of the test bodies to the carriers,teeth have been cast using Wiron 88. This is an essential procedure, since any plastical deformation of the carriers would have had an influence on further results, which had to be avoided by any means. To summarize,our results show the strength provided by In-Ceram® for Incisivi/Canini applications when compared to traditional VMK applications.","abstract_html":"This PhD Thesis is to prove if In-Ceram® (Registered Trademak by Vita) implemented in Incisivi/Caninicrowns provides sufficient strength when being exposed to artificial salivar, to be applied like VMK in the field of aesthetical front-tooth dental treatment. Our trials have been based on &quot;Normkronentest&quot; by Voss, to provide a scenario being compatible with findings resulting from rather traditional Verblendkronen applications. No significant influence of exposure to Fusajama salivar on the fracture strength could be stated. Also,comparisons of Incisivi/Canini parameters did not lead to significant differences. To gain a test body,we chose slurry lamination instead of an injection technique, to allow a higher degree of practical relevance. According to specifications by Vita,both an Incisivus and a Caninus were designed with rounded layers in a four-degree convergence angle. To assure a perfect fitting of the test bodies to the carriers,teeth have been cast using Wiron 88. This is an essential procedure, since any plastical deformation of the carriers would have had an influence on further results, which had to be avoided by any means. To summarize,our results show the strength provided by In-Ceram® for Incisivi/Canini applications when compared to traditional VMK applications.","abstract_has_math":false,"creators":["Segschneider, Paul Thomas"],"institution":"Publikationsserver der RWTH Aachen University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Lampert, Friedrich"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-07-30T19:40:33Z","subjects":["info:eu-repo/classification/ddc/610","Bruchfestigkeit","Festsitzender Zahnersatz","Zahnersatz","Medizin","Vita In-Ceram","vollkeramischer Zahnersatz","all ceramic Crown"],"languages":["ger"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://publications.rwth-aachen.de/search?p=id:%22RWTH-CONV-113434%22"],"render_values":[{"text":"https://publications.rwth-aachen.de/search?p=id:%22RWTH-CONV-113434%22","href":"https://publications.rwth-aachen.de/search?p=id:%22RWTH-CONV-113434%22","code":true}]}]},"links":{"outbound_url":"https://publications.rwth-aachen.de/record/51118","outbound_label":"Repository record","outbound_source":"dc:identifier"},"source_record":{"url":"https://publications.rwth-aachen.de/oai2d?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Apublications.rwth-aachen.de%3A51118","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lampert, Friedrich"]},{"key":"dc:creator","label":"Author","values":["Segschneider, Paul Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:coverage","label":"Dc Coverage","values":["DE"]},{"key":"dc:date","label":"Dc Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Publikationsserver der RWTH Aachen University"]},{"key":"dc:relation","label":"Dc Relation","values":["info:eu-repo/semantics/altIdentifier/urn/urn:nbn:de:hbz:82-opus-27612"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/doctoralThesis","info:eu-repo/semantics/publishedVersion"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["info:eu-repo/classification/ddc/610","Bruchfestigkeit","Festsitzender Zahnersatz","Zahnersatz","Medizin","Vita In-Ceram","vollkeramischer Zahnersatz","all ceramic Crown"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["ger"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://publications.rwth-aachen.de/record/51118","https://publications.rwth-aachen.de/search?p=id:%22RWTH-CONV-113434%22"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This PhD Thesis is to prove if In-Ceram® (Registered Trademak by Vita) implemented in Incisivi/Caninicrowns provides sufficient strength when being exposed to artificial salivar, to be applied like VMK in the field of aesthetical front-tooth dental treatment. Our trials have been based on \"Normkronentest\" by Voss, to provide a scenario being compatible with findings resulting from rather traditional Verblendkronen applications. No significant influence of exposure to Fusajama salivar on the fracture strength could be stated. Also,comparisons of Incisivi/Canini parameters did not lead to significant differences. To gain a test body,we chose slurry lamination instead of an injection technique, to allow a higher degree of practical relevance. According to specifications by Vita,both an Incisivus and a Caninus were designed with rounded layers in a four-degree convergence angle. To assure a perfect fitting of the test bodies to the carriers,teeth have been cast using Wiron 88. This is an essential procedure, since any plastical deformation of the carriers would have had an influence on further results, which had to be avoided by any means. To summarize,our results show the strength provided by In-Ceram® for Incisivi/Canini applications when compared to traditional VMK applications."]},{"key":"dc:source","label":"Dc Source","values":["Aachen : Publikationsserver der RWTH Aachen University 81 S. : Ill., graph. Darst. (2009). = Aachen, Techn. Hochsch., Diss., 2009"]},{"key":"dc:title","label":"Title","values":["Untersuchung zur Veränderung der mechanischen Festigkeit von In-Ceram-Kronen in Abhängigkeit von der Lagerung in Kunstspeichel"]}]}],"canonical_facts":{"dc:contributor":["Lampert, Friedrich"],"dc:coverage":["DE"],"dc:creator":["Segschneider, Paul Thomas"],"dc:date":["2009"],"dc:description":["This PhD Thesis is to prove if In-Ceram® (Registered Trademak by Vita) implemented in Incisivi/Caninicrowns provides sufficient strength when being exposed to artificial salivar, to be applied like VMK in the field of aesthetical front-tooth dental treatment. Our trials have been based on \"Normkronentest\" by Voss, to provide a scenario being compatible with findings resulting from rather traditional Verblendkronen applications. No significant influence of exposure to Fusajama salivar on the fracture strength could be stated. Also,comparisons of Incisivi/Canini parameters did not lead to significant differences. To gain a test body,we chose slurry lamination instead of an injection technique, to allow a higher degree of practical relevance. According to specifications by Vita,both an Incisivus and a Caninus were designed with rounded layers in a four-degree convergence angle. To assure a perfect fitting of the test bodies to the carriers,teeth have been cast using Wiron 88. This is an essential procedure, since any plastical deformation of the carriers would have had an influence on further results, which had to be avoided by any means. To summarize,our results show the strength provided by In-Ceram® for Incisivi/Canini applications when compared to traditional VMK applications."],"dc:identifier":["https://publications.rwth-aachen.de/record/51118","https://publications.rwth-aachen.de/search?p=id:%22RWTH-CONV-113434%22"],"dc:language":["ger"],"dc:publisher":["Publikationsserver der RWTH Aachen University"],"dc:relation":["info:eu-repo/semantics/altIdentifier/urn/urn:nbn:de:hbz:82-opus-27612"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:source":["Aachen : Publikationsserver der RWTH Aachen University 81 S. : Ill., graph. Darst. (2009). = Aachen, Techn. Hochsch., Diss., 2009"],"dc:subject":["info:eu-repo/classification/ddc/610","Bruchfestigkeit","Festsitzender Zahnersatz","Zahnersatz","Medizin","Vita In-Ceram","vollkeramischer Zahnersatz","all ceramic Crown"],"dc:title":["Untersuchung zur Veränderung der mechanischen Festigkeit von In-Ceram-Kronen in Abhängigkeit von der Lagerung in Kunstspeichel"],"dc:type":["info:eu-repo/semantics/doctoralThesis","info:eu-repo/semantics/publishedVersion"]},"updated_at":"2026-07-30T19:40:33Z"}