Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"time-gated"”.

  1. A Time-Gated Fluorescence Instrument and Its Applications Using Mn-Doped I(II)-III-VI Nanocrystal Probes

    … this work, two versions of a low-cost, portable, time-gated fluorescence intensity measurement instrument were developed with the primary aim of utilizing Mn-doped I(II)-III-VI nanocrystals (Mn:AgZnInS/ZnS and Mn:CuZnInS/ZnS core/shell) as long-lifetime fluorescent probes for sensing applications. …

    unr Repository record for A Time-Gated Fluorescence Instrument and Its Applications Using Mn-Doped I(II)-III-VI Nanocrystal Probes (opens in a new tab)

  2. The photophysics properties of lanthanide luminescent probes

    … study of the luminescence quantum yield, lifetimes and the number of water molecules coordinated to lanthanide luminescent probes based on biphenylyl-7-amino-4- methyl-2(1H)-quinolinon (Bi-cs124) derivatives have been carried out using a time- resolved fluorescence assay (TRFA). Bi-cs124 was …

    njit Repository record for The photophysics properties of lanthanide luminescent probes (opens in a new tab)

  3. Observation and Characterization of Trends in the Ionization of the Warm Absorber Photoionized Plasma Experiment at Z

    … uses a cm-scale gas cell placed several centimeters from the z-pinch to contain neon gas of atom number densities 10$^{17}$ -- 10$^{18}$ cm$^{-3}$. Windows along the line of sight to a spectrometer allow (1) the radiation from the z-pinch to pass through the cell and drive the system and (2) …

    unr Repository record for Observation and Characterization of Trends in the Ionization of the Warm Absorber Photoionized Plasma Experiment at Z (opens in a new tab)

  4. Advanced Raman spectroscopy for bioprocess monitoring

    … discovered almost 90 years ago. It took a long time until the importance of Raman spectroscopy was fully understood and accepted for process industrial applications. Still today the usage is limited to a small application area. During the last decades advances in the production of spectroscopic …

    tu-berlin Repository record for Advanced Raman spectroscopy for bioprocess monitoring (opens in a new tab)

  5. Theoretical and Experimental Studies of Radiation from Z-Pinch Complex Wire Arrays and Applications

    … of diagnostics, in particular a newly developed time-gated hard x-ray spectrometer to gain an understanding as to how these plasmas radiate in time, particularly in the 0.7 - 4.4 Å range. The experiments predominately took place on the 1.7 MA Zebra generator at the Nevada Terawatt Facility (NTF) …

    unr Repository record for Theoretical and Experimental Studies of Radiation from Z-Pinch Complex Wire Arrays and Applications (opens in a new tab)

  6. Characterization and applications of pulsed millisecond glow discharge sources

    … discrimination of isobaric interferences using time-gated detection, an example would be the determination of 40Ca + from 40Ar+. Further exploitation of these temporal regimes can be applied to molecular analysis, where concurrent molecular and structural information can be obtained.

    wvu Repository record for Characterization and applications of pulsed millisecond glow discharge sources (opens in a new tab)

  7. Fluorescent silicon nanocrystals for bioimaging

    … to two-photon excitation, and can be conjugated to a wide variety of targeting molecules. Silicon (Si) nanocrystal quantum dots in particular exhibit bright, size-dependent emission with visible to near infrared wavelengths and are biocompatible, making them potentially interesting for in …

    texas Repository record for Fluorescent silicon nanocrystals for bioimaging (opens in a new tab)

  8. Development and application of correlative STED and AFM to investigate neuronal cells

    … of a range of STED techniques (cw-STED, time-gated STED, pulsed STED and RESOLFT) were compared, identifying that pulsed STED theoretically has the highest photon efficiency. A pulsed STED microscope, which uses adaptive optics, was then designed, developed and characterised. The …

    cambridge Repository record for Development and application of correlative STED and AFM to investigate neuronal cells (opens in a new tab)

  9. Precise optical manipulation techniques for exploring neuronal function

    … in the analysis of their function, namely time-gated holographic two-photon photostimulation and femtosecond laser dendrotomy. At the start of this thesis, no illumination technique had been able to activate synapses along the three-dimensional (3D) dendritic arbour of a neuron using …

    aus-cath Repository record for Precise optical manipulation techniques for exploring neuronal function (opens in a new tab)

  10. Precise optical manipulation techniques for exploring neuronal function

    … in the analysis of their function, namely time-gated holographic two-photon photostimulation and femtosecond laser dendrotomy. At the start of this thesis, no illumination technique had been able to activate synapses along the three-dimensional (3D) dendritic arbour of a neuron using …

    anu Repository record for Precise optical manipulation techniques for exploring neuronal function (opens in a new tab)

  11. Development of luminescent probes for ultrasensitive detection of biopolymers, their complexes, and living cells

    … of their long-lived emission signal in time- resolved mode, which avoids short-lived background fluorescence of the medium. Two model carbostyril fluorophores (cs 124-CH_3 and cs 124-CF_3) were modified by inclusion of two spacers (diamino and bi-phenyl) for the attachment of amine and …

    njit Repository record for Development of luminescent probes for ultrasensitive detection of biopolymers, their complexes, and living cells (opens in a new tab)

  12. Reducing interferences in glow discharge spectroscopies using transient operation and collision -induced dissociation

    … ions. This could lead to future applications for time-gated detection methods in optical and mass spectrometric analyses that minimize interferences due to plasma species.;Collision-induced dissociation of strongly bound molecular interferences in a quadrupole ion trap is examined as a potential …

    wvu Repository record for Reducing interferences in glow discharge spectroscopies using transient operation and collision -induced dissociation (opens in a new tab)

  13. The design and synthesis of fluorescent peptides and disaccharides for tumour imaging.

    … most effective energy transfer mediated long-lifetime luminescent combinations, for subsequent attachment to the cyclic peptide as long-lifetime imaging agents which would allow the use of time-gated technology to eliminate troublesome background fluorescence. This chemistry was published. Near-IR …

    birmingham Repository record for The design and synthesis of fluorescent peptides and disaccharides for tumour imaging. (opens in a new tab)

  14. Luminescent Lanthanide Complexes and Nanoparticles for Biological Applications

    … applications because of their long emission lifetimes, sharp emission bands, color purity, resistance to photobleaching, and enhanced signal-to-noise ratios. Their practical use in aqueous and biological systems requires organic chromophores or other organic ligands that provide water solubility …

    unr Repository record for Luminescent Lanthanide Complexes and Nanoparticles for Biological Applications (opens in a new tab)

  15. Radiatively Cooled Magnetic Reconnection Experiments Driven by Pulsed Power

    … wire array, driven by a 20 MA peak, 300ns rise time current generated by the Z pulsed-power machine (Sandia National Labs). The load generates oppositely-directed supersonic, super-Alfvénic, collisional plasma flows with anti-parallel magnetic fields, that generate a reconnection layer …

    mit Repository record for Radiatively Cooled Magnetic Reconnection Experiments Driven by Pulsed Power (opens in a new tab)

  16. Development of methods for the detection of chemical and biological warfare agents

    … pulse widths and duty cycles. For the first time, the behavior of argon doubly charged species was characterized in these pulsed plasmas. Whereas the goal of Chapter 2 was to understand the fundamental characteristics of the pulsed glow discharge, Chapters 3 and 4 strive to expand its future …

    wvu Repository record for Development of methods for the detection of chemical and biological warfare agents (opens in a new tab)

  17. Single-Molecule Characterization of Photophysical and Colloidal Properties of Biocompatible Quantum Dots

    … high photostability and long fluorescent lifetimes (on the order of tens of nanoseconds) — make them attractive probes in experiments involving long observation times, multicolor and time-gated detection. Photophysical properties were investigated at the ensemble and single-molecule level for …

    heid-diss Repository record for Single-Molecule Characterization of Photophysical and Colloidal Properties of Biocompatible Quantum Dots (opens in a new tab)