  1. THROMBUS GENERATION UNDER FLOW CONDITIONS IN PATIENTS WITH CIRRHOSIS AND THROMBOCYTOPENIA: THE CIRTAS-STUDY

    … cirrhosis. Global hemostasis assays, including thromboelastometry and thrombin generation, are valid alternatives, however, despite their relevant contribution to understand the complexity of hemostasis in advanced chronic liver disease, they are not recommended for the bleeding risk …

    milano Repository record for THROMBUS GENERATION UNDER FLOW CONDITIONS IN PATIENTS WITH CIRRHOSIS AND THROMBOCYTOPENIA: THE CIRTAS-STUDY (opens in a new tab)

  2. Clotting analysis of blood samples from intensive care unit patients.

    … low- dose tissue factor activated rotational thromboelastometry and the clot formation and lysis assay]. Results: Clot initiation in both whole blood and plasma analysis was prolonged in the intensive care unit samples. This was observed in the global assay analysis and was elucidated by the …

    de-montfort Repository record for Clotting analysis of blood samples from intensive care unit patients. (opens in a new tab)

  3. In-vitro Clot Formation and Failure

    … including thrombelastograpy (TEG) and rotational thromboelastometry (ROTEM). However, these devices (TEG/ROTEM) are not ideal modalities for assessing clot mechanical properties in trauma conditions due to the amount of time taken to obtain results, poor sensitivity, repeatability, and lack of …

    washington Repository record for In-vitro Clot Formation and Failure (opens in a new tab)

  4. Does an objective laboratory measurement of platelet quality correlate with clinical efficacy?

    … analyser, the ThromboLUX instrument, rotation thromboelastometry (ROTEM) and an automated, simplified version of the HSR test named the automated water expulsion (AWE) test. After initial technical development of the assays, a study of the test results obtained throughout platelet concentrate …

    oxford-brookes Repository record for Does an objective laboratory measurement of platelet quality correlate with clinical efficacy? (opens in a new tab)

  5. The Use of Synthetic Platelets to Augment Hemostasis

    … to 92%. In vitro analysis using rotational thromboelastometry (ROTEM) confirmed the increased dose-sensitivity of GRGDS-NP100 and laid the foundation for methods to determine optimal ligand concentration parameters. Hemostatic nanoparticles were then tested in a clinically relevant porcine …

    ohiolink Repository record for The Use of Synthetic Platelets to Augment Hemostasis (opens in a new tab)

  6. Viscoelastic haemostatic assays and fibrinogen concentration tests during haemodilution: The effects of fibrinogen and factor XIII

    … Coagulation was assessed with rotational thromboelastometry (ROTEM) or free oscillation rheometry (FOR) in vitro and different fibrinogen measurement methods in observational studies. Results: Haemodilution with human albumin (HA) impaired clot strength (EXTEM MCF, maximal clot formation) …

    lund Repository record for Viscoelastic haemostatic assays and fibrinogen concentration tests during haemodilution: The effects of fibrinogen and factor XIII (opens in a new tab)

  7. The effects of hypothermia and acidosis on Haemostasis

    … time (APTT), the ROTEM® analyzer to assess thromboelastometry and the Fluoroscan Ascent to assess thrombin generation using calibrated automated thrombography (CAT). The results show a difference in interpretation between assays using fibrin polymerisation as an end-point as opposed to the …

    de-montfort Repository record for The effects of hypothermia and acidosis on Haemostasis (opens in a new tab)