Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 322 for “"temperature measurements"”.

  1. Gas temperature measurements by ultrasonic pulse method

    Thesis (Sc.D.) Massachusetts Institute of Technology. Dept. of Electrical Engineering, 1955.

    mit Repository record for Gas temperature measurements by ultrasonic pulse method (opens in a new tab)

  2. Unsteady surface heat flux and temperature measurements

    … measure the time-resolved surface heat flux and temperature from a turbulent combustion flame impinging on a surface. Using the analytical semi-infinite conduction model, the unsteady surface heat flux was calculated from the transient temperature measurements and the surface temperature was …

    vt Repository record for Unsteady surface heat flux and temperature measurements (opens in a new tab)

  3. Noninvasive Temperature Measurements Using Electron Paramagnetic Resonance Spectroscopy

    … that may be used for non-invasive in vivo temperature measurements in living systems. We use the nitroxide, 3-doxyl-5$\alpha$-cholestane, mixed in 1 mol% cholesterol and 99 mol% methyl docosanoate and encapsulated in proteinaceous microspheres (average diameter $<$2 $\mu$m). We have shown a …

    uiuc Repository record for Noninvasive Temperature Measurements Using Electron Paramagnetic Resonance Spectroscopy (opens in a new tab)

  4. Extended Surface Heat Transfer Coefficients via Endwall Temperature Measurements

    … computation of heat transfer rates via pin base temperature measurements via Temperature Sensitive Paint, or similar non-intrusive methods. Verification of this method is done with comparisons to the solution of infinite fins with internal heat generation, conjugate computational results, and …

    embry-riddle Repository record for Extended Surface Heat Transfer Coefficients via Endwall Temperature Measurements (opens in a new tab)

  5. Estimation of Unsteady Nonuniform Heating Rates from Surface Temperature Measurements

    … impinge on a test cylinder, where the temperature due to the heat flux is measured. These measurements are used to estimate the heat flux on the surface as a result of the shock interactions. The nature of the incident flux usually involves dynamic transients and severe nonuniformities. …

    vt Repository record for Estimation of Unsteady Nonuniform Heating Rates from Surface Temperature Measurements (opens in a new tab)

  6. Direct Ion-Temperature Measurements Using High-Resolution Inelastic X-ray Scattering

    Temperature in high-energy-density (HED) materials has been a long-standing problem. Direct temperature measurements are challenging because HED samples are often opaque and have extremely short lifetimes. Historically, ion temperature has been inferred from structural measurements that serve only …

    unr Repository record for Direct Ion-Temperature Measurements Using High-Resolution Inelastic X-ray Scattering (opens in a new tab)

  7. Nanometer-scale temperature measurements of phase change memory and carbon nanomaterials

    … in new electronic devices. Comparing measurements and predictions of CVD graphene heating predicted the resistivity, voltage drop, and temperature rise across the one dimensional (1D) GB defects. This work measured the nanometer-scale temperature rise of thin film Ge2Sb2Te5 (GST) based …

    uiuc Repository record for Nanometer-scale temperature measurements of phase change memory and carbon nanomaterials (opens in a new tab)

  8. Temperature measurements in a flow using laser induced fluorescence of oxygen

    Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 1992.

    mit Repository record for Temperature measurements in a flow using laser induced fluorescence of oxygen (opens in a new tab)

  9. Mass flow and temperature measurements in the flue of a woodburning appliance

    … loss due to the flue gases being at a higher temperature than the ambient. 2. Chemical energy loss from incomplete combustion. 3. Latent energy loss due to water existing as a vapor in the flue gas. This loss is included since the higher heating value of wood is used. The instantaneous …

    vt Repository record for Mass flow and temperature measurements in the flue of a woodburning appliance (opens in a new tab)

  10. An Approach to Thermocouple Temperature Measurements that Reduces Uncertainties Associated with Radiative Corrections

    <p>Obtaining accurate temperature measurements in flame environments with thermocouples is extremely challenging due to the effects of radiative heat loss. These losses are difficult to quantify and often cannot be corrected for or minimized without sacrificing spatial resolution. In this work, a …

    wustl Repository record for An Approach to Thermocouple Temperature Measurements that Reduces Uncertainties Associated with Radiative Corrections (opens in a new tab)

  11. Development of Fiber Optic Sensors using Femtosecond Laser for Refractive Index and Temperature Measurements

    … for measurement of ambient refractive index and temperature. The femtosecond laser operating at 780 nm with pulse duration of 172 fs and pulse repetition rate of 1 kHz is used to study bulk index modification and fabricate fiber long period and short period gratings. Effective and reliable …

    uvic Repository record for Development of Fiber Optic Sensors using Femtosecond Laser for Refractive Index and Temperature Measurements (opens in a new tab)

  12. On temperature measurements and analysis in electron beam additive manufacturing using near infrared thermography

    … the ability to accurately measure process temperatures is necessary before process models can be validated and closed-loop feedback control systems can be developed. Knowledge of the cooling rates experienced by the part during fabrication is also essential for the development of predictive …

    alabama Repository record for On temperature measurements and analysis in electron beam additive manufacturing using near infrared thermography (opens in a new tab)

  13. Low -Frequency 1/F Noise: Low Temperature Measurements and Effect on Superconducting Qubit Dephasing

    … work is to measure this noise as a function of temperature and to simulate its effect on the measurement dynamics associated with superconducting qubits. In Nb trilayer junctions we measure the noise power at 1 Hz down to 10 mK and verify a T2 dependence for T > 1 K, below which we observe a …

    uiuc Repository record for Low -Frequency 1/F Noise: Low Temperature Measurements and Effect on Superconducting Qubit Dephasing (opens in a new tab)

  14. Low-frequency 1/f noise : low temperature measurements and effect on superconducting qubit dephasing

    … work is to measure this noise as a function of temperature and to simulate its effect on the measurement dynamics associated with superconducting qubits. In Nb trilayer junctions we measure the noise power at 1 Hz down to 10 mK and verify a T2 dependence for T > 1 K, below which we observe a …

    uiuc Repository record for Low-frequency 1/f noise : low temperature measurements and effect on superconducting qubit dephasing (opens in a new tab)

  15. Depletion, quantum jumps, and temperature measurements of ⁸⁸Sr⁺ ions in a linear Paul Trap

    … the spectrum to a Voigt function yielded an ion temperature of 35 mK. To avoid blue-broadening, we set up blue and red laser pulse sequences. This allowed us to observe a red spectrum with secular sidebands and calculate an ion temperature of 6.8 +4.4 / -2.2 mK.

    mit Repository record for Depletion, quantum jumps, and temperature measurements of ⁸⁸Sr⁺ ions in a linear Paul Trap (opens in a new tab)

  16. Monochromator-based absolute calibration of radiation thermometers for thermodynamic temperature measurements of high-temperature fixed-points

    … Strahlungsgesetz und ausgehend von den Temperaturen des erstarrenden Silber, Gold oder Kupfers definiert ist. Alternativ dazu erlaubt die absolute radiometrische Strahlungsmessung eine direkte Temperaturbestimmung rückgeführt auf ein kryogenes elektrisches Substitutionsradiometer als …

    tu-berlin Repository record for Monochromator-based absolute calibration of radiation thermometers for thermodynamic temperature measurements of high-temperature fixed-points (opens in a new tab)

Page 1 of 17