Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 110 for “"pmu"”.

  1. A Method for PMU-Based Reconfigurable Monitoring

    … to ensure stability. Phasor Measurement Units (PMUs) provide very good observation of a small area of a network, but their relatively high cost prevents them from being deployed at every point. Therefore, to monitor an entire network, State Estimation is still required. By combining these two …

    vt Repository record for A Method for PMU-Based Reconfigurable Monitoring (opens in a new tab)

  2. Minimal PMU placement for graph observability: a decomposition approach

    This thesis explores the PMU placement problem, that is, the placement of a minimal number of Phase Measurement Units (PMUs) on the nodes of a power system graph such that the entire graph is observed. The NP-completeness of PMU placement for planar bipartite graphs is shown. PMU placement …

    vt Repository record for Minimal PMU placement for graph observability: a decomposition approach (opens in a new tab)

  3. On the application of PMU measurements to system stability analysis

    … to analyze power system stability by utilizing PMU measurements. As the current power system is operated close to its limits, stability is of high concern for both operators and customers. The implementation of phasor measurement units across the power system allows for accurate and fast …

    uiuc Repository record for On the application of PMU measurements to system stability analysis (opens in a new tab)

  4. A Practical Comprehensive Approach to PMU Placement for Full Observability

    … the placement of phasor measurement units (PMUs) in electric transmission systems has gained much attention. Engineers and mathematicians have developed a variety of algorithms to determine the best locations for PMU installation. But often these placement algorithms are not practical for …

    vt Repository record for A Practical Comprehensive Approach to PMU Placement for Full Observability (opens in a new tab)

  5. Fast power network detection of topology change locations using PMU measurements

    … states obtained from phasor measurement units (PMUs). This scheme can be applied on reduced systems where parts of the network are not covered by PMU measurements. The scheme was tested during different outage events in the IEEE39-bus system. The obtained results validated the algorithm’s …

    utc Repository record for Fast power network detection of topology change locations using PMU measurements (opens in a new tab)

  6. On Verification of Load Models for Frequency Response Using PMU Data

    … based on real-life frequency excursions. PMU data collected in Alberta’s grid is used for the scope of studies. Load models explored include CLOD, ZIP and exponential load models. Furthermore, measurement-based load modeling is defined to optimize the load model parameters to improve the …

    calgary Repository record for On Verification of Load Models for Frequency Response Using PMU Data (opens in a new tab)

  7. Application of PMU for system stability analysis with Thevenin equivalent modeling

    … stability by utilizing phasor measurement units (PMUs). In the past decades, industrialization has expanded rapidly around the world, and the demand for stable and reliable power sources has increased. Therefore, maintaining stable operation of the power system is an imperative and urgent issue. …

    uiuc Repository record for Application of PMU for system stability analysis with Thevenin equivalent modeling (opens in a new tab)

  8. PMU-Based Applications for Improved Monitoring and Protection of Power Systems

    … and doing data conditioning. The role of PMUs in fulfilling these four objectives forms the basis of this dissertation. Classification and regression tree (CART) built using phasor data has been extensively used in power systems. The splits in CART are based on a single attribute or a …

    vt Repository record for PMU-Based Applications for Improved Monitoring and Protection of Power Systems (opens in a new tab)

  9. Phasor Measurement Unit (PMU) : based system for event detection on synchronous generators

    … sometimes seen in the Phasor Measurement Unit (PMU) data in the Icelandic power system, probably due to the small size. The use of PMU data with event detection algorithms, along with modeling, could be a method of capturing these events for analysis. The goals of this thesis are to develop an …

    reykjavik Repository record for Phasor Measurement Unit (PMU) : based system for event detection on synchronous generators (opens in a new tab)

  10. Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks

    … System (WAMS) and Phasor Measurement Unit (PMU), various fault location algorithms have been proposed. The purpose of this work is to determine, modify and test the most appropriate fault location method which can be implemented with a PMU only linear state estimator. The thesis reviews …

    vt Repository record for Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks (opens in a new tab)

  11. A predictive out-of-step protection scheme based on PMU enabled distributed dynamic state estimation

    … compared to conventional metering devices. PMUs provide synchronized measurements, where synchronization is achieved via a GPS clock which provides the synchronizing signal with accuracy of 1 μsec. As a result, the computed phasors have a common reference (UTC time) and can be used in local …

    gatech Repository record for A predictive out-of-step protection scheme based on PMU enabled distributed dynamic state estimation (opens in a new tab)

  12. Renewable Energy Integrated Power System Stability Assessment with Validated System Model Based on PMU Measurements

    … transmission line parameters in the system with PMU measurements. The system transient stability assessment is conducted based on this validated model. The constrained stability region is estimated with Lyapunov functions family based method in the center of angles reference frame considering …

    vt Repository record for Renewable Energy Integrated Power System Stability Assessment with Validated System Model Based on PMU Measurements (opens in a new tab)

  13. PMU-Driven Fault Location in Distribution Systems with DERs: Impedance-Based and Multi-Agent System Strategies

    … providers. With the increasing deployment of PMUs in distribution networks, this study leverages synchrophasor measurements for fault location, addressing gaps in the existing literature. Conventional fault location methods often rely on centralized architectures, creating a single point of …

    sask Repository record for PMU-Driven Fault Location in Distribution Systems with DERs: Impedance-Based and Multi-Agent System Strategies (opens in a new tab)

  14. Perceptions of Metabolic Syndrome Management Utilization in relation with Patient Characteristics and Health-related Quality of Life

    … of disease management resource utilization (PMU). Therefore, understanding patients' PMU is crucial for improving health outcomes. The study investigated PMU, explored PMU predictors, and investigated the impact of PMU and patients’ demographics on HRQoL. Using a cross-sectional design, data …

    chapman Repository record for Perceptions of Metabolic Syndrome Management Utilization in relation with Patient Characteristics and Health-related Quality of Life (opens in a new tab)

  15. Applications of PMUSimulator in PDC Testing

    … essential for real time control of the system. PMUs are time synchronized throughout the power system and take sample measurements in very small windows of time. Phasor Data Concentrators accept PMU data and time align the data so that a snapshot of the power system can be viewed in real time. …

    vt Repository record for Applications of PMUSimulator in PDC Testing (opens in a new tab)

  16. Cooperative congestion control in power grid communication networks

    … for the delivery of Phasor Measurement Unit (PMU) sensor data with real time guarantees to the control centers for timely decisions. Present day network systems are unable to ensure the real-time needs of the PMU data as they are not designed to support PMU devices. Hence, the need arises for …

    uiuc Repository record for Cooperative congestion control in power grid communication networks (opens in a new tab)

  17. Optimal Substation Coverage for Phasor Measurement Unit Installations

    The PMU has been found to carry great deal of value for applications in the wide area monitoring of power systems. Historically, deployment of these devices has been limited by the prohibitive cost of the device itself. Therefore, the objective of the conventional optimal PMU placement problem is …

    vt Repository record for Optimal Substation Coverage for Phasor Measurement Unit Installations (opens in a new tab)

  18. Understanding Problematic Media Use in Children and Youth with ADHD, Early Neurological Risk and a Community Sample: Exploring Parental Cognitions and Perspectives

    … as more susceptible to problematic media use (PMU), less emphasis has been placed on understanding these vulnerable groups. Current theories of PMU draw from a psychopathology framework, aiming to distinguish normal variation from pathological behaviour. Measures like the Problematic Media Use …

    york Repository record for Understanding Problematic Media Use in Children and Youth with ADHD, Early Neurological Risk and a Community Sample: Exploring Parental Cognitions and Perspectives (opens in a new tab)

  19. Event Detection and Visualization Based on Phasor Measurement Units for Improved Situational Awareness

    … the new methods presented for the processing of PMU data, techniques for visualization of PMU data in its processed and unprocessed forms are described. A new technique based on graphical processing units (GPUs), developed to allow rendering speeds to match the relatively fast data rate of PMUs, …

    uiuc Repository record for Event Detection and Visualization Based on Phasor Measurement Units for Improved Situational Awareness (opens in a new tab)

Page 1 of 6