  1. Improved accuracy in susceptibility-based OEF measurements by mitigation of partial-volume effects via combined magnitude and phase reconstruction

    … limit produce unreliable measurements due to partial-volume effects. We demonstrate a method for obtaining more reliable OEF measurements beyond this limit by performing a joint reconstruction using both the magnitude and phase of the complex-valued MRI signal. This method is validated both in …

    mit Repository record for Improved accuracy in susceptibility-based OEF measurements by mitigation of partial-volume effects via combined magnitude and phase reconstruction (opens in a new tab)

  2. Fabrication and Testing of a Microchannel Network Phantom for MRI Velocimetry

    … Slice thickness, order of image acquisition, partial volume effects, and acceleration effects are investigated, and show little effect on the measured flow rates. Examination of anatomical MR images show that the channels decreased in height during fabrication, which explains some of the …

    uiuc Repository record for Fabrication and Testing of a Microchannel Network Phantom for MRI Velocimetry (opens in a new tab)

  3. Optimization of the Fair Technique for Specific Brain Region Perfusion Studies

    … inversion with a control for off-resonance effects) for quantifying cerebellum perfusion. The data indicate that FAIR ASST yields more robust CBF (cerebral blood flow) measurements. OPTIMAL FAIR (orthogonally-positioned tagging imaging method for arterial labeling of FAIR) was developed and …

    utswmed Repository record for Optimization of the Fair Technique for Specific Brain Region Perfusion Studies (opens in a new tab)

  4. MR-assisted PET data optimization for simultaneous dual-modality imaging in dementia

    … image degradation due to subject movements; partial volume effects correction is required due to the relatively limited spatial resolution. Although many applications could benefit from these methodological improvements, in this thesis we focused on dementia. MRI and PET are widely used and …

    mit Repository record for MR-assisted PET data optimization for simultaneous dual-modality imaging in dementia (opens in a new tab)

  5. Intercomparison of medical image segmentation algorithms

    … it suffers from artefacts including noise, partial volume effects and intensity inhomogeneities.Brain, being a very complicated structure, its precise segmentation is particularly necessary to delineate the borders of anatomically distinct regions and possible tumors. Many algorithms have …

    strathclyde Repository record for Intercomparison of medical image segmentation algorithms (opens in a new tab)

  6. Advanced Methods for Diffusion MRI Data Analysis and their Application to the Healthy Ageing Brain

    … dispersion simultaneously. Fourthly, free water volume fraction estimates provided by the free water diffusion tensor imaging (fwDTI) are shown to be useful to detect and remove voxels corrupted by cerebrospinal fluid (CSF) partial volume effects. Finally, dMRI techniques are applied to the …

    cambridge Repository record for Advanced Methods for Diffusion MRI Data Analysis and their Application to the Healthy Ageing Brain (opens in a new tab)

  7. MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach

    … on the reference CT. Finally, a target volume shift was simulated and employing a hybrid approach, a treatment plan adapted to the shift was optimized on the basis of a so-called corrected CT. The latter consisted of a reference CT, in which a volume around the target was replaced by …

    heid-thes Repository record for MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach (opens in a new tab)

  8. High-Resolution Diffusion Tensor Imaging and Human Brain Connectivity

    … with diverse diffusion properties. As such, partial volume effects introduce a strong bias which can lead to spurious measurements, especially in regions with a complex tissue structure such as interdigitating crossing fibers or in convoluted cortical folds near the grey/white matter …

    duke Repository record for High-Resolution Diffusion Tensor Imaging and Human Brain Connectivity (opens in a new tab)

  9. fMRI for mapping the plastic somatotopy of primary somatosensory cortex - Development and clinical applications

    Functional magnetic resonance imaging (fMRI) is a widely used tool for studying brain function in vivo. The technique is based on acquiring brain images sensitive to the physiological response following neural activation, and hence, allows brain activity to be examined and documented. In this …

    lund Repository record for fMRI for mapping the plastic somatotopy of primary somatosensory cortex - Development and clinical applications (opens in a new tab)