Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"linear position transducer"”.

  1. Sleeping to perform: examining sleep and exercise in elite female athletes

    … One assessed the reliability and validity of a linear position transducer device as a performance tool for further studies within the thesis. Study Two subjectively and objectively assessed sleep indices in the night leading up to and the nights following competition over a netball season. Study …

    waikato-masters Repository record for Sleeping to perform: examining sleep and exercise in elite female athletes (opens in a new tab)

  2. The load that maximises the mechanical power output in the power clean: A comparison between different relative strength levels

    … between 50%-100% of 1 RM of their power clean. A linear position transducer (LPT) was used to measure bar displacement and power output was calculated using both system mass (LPT SM) and bar mass (LPT BM) calculation methods. A mixed factorial design was used to determine whether there was a …

    edithcowan Repository record for The load that maximises the mechanical power output in the power clean: A comparison between different relative strength levels (opens in a new tab)

  3. Kinetic, Kinematic, and Metabolic Response of Low Volume Accentuated Eccentric Loading in Collegiate Weightlifters

    … were collected via synchronized force plate and linear position transducer. Metabolic parameters assessed were oxygen consumption (VO2 ) using open circuit spirometry, testosterone (T) and cortisol (C) via blood draw from antecubital vein, and lactate (La) values via finger prick blood draw. The …

    etsu Repository record for Kinetic, Kinematic, and Metabolic Response of Low Volume Accentuated Eccentric Loading in Collegiate Weightlifters (opens in a new tab)

  4. The acute effects of transcranial direct current stimulation on the performance of velocity based squat training

    … measuring average propulsive velocities using a linear position transducer. In addition, participants reported their perception of exertion using the OMNI-RES scale immediately after each set in order to assess subjective levels of fatigue and exertion. The results indicated that thirteen of the …

    murcia-diss Repository record for The acute effects of transcranial direct current stimulation on the performance of velocity based squat training (opens in a new tab)

  5. Factors related to creating force-velocity and load-velocity profiles with the squat jump

    … were compared with a laboratory based four-linear position transducer system (4- LPT) in order to determine if the velocities measured with these devices agreed and were reliable. In Study 4, the mode of exercise (free-weight or Smith Machine) was compared to determine if there was agreement …

    edithcowan Repository record for Factors related to creating force-velocity and load-velocity profiles with the squat jump (opens in a new tab)

  6. Bilateral and unilateral resistance training and athletic performance

    … 160-169kg and 180-189kg) including: 1) Linear Position Transducer attached 65cm left of barbell centre, 2) 3D motion analysis tracking of markers attached to either end of the barbell, and 3) cervical marker (C7) (criterion measurement). Validity was calculated using typical error of the …

    edithcowan Repository record for Bilateral and unilateral resistance training and athletic performance (opens in a new tab)

  7. Monitoring neuromuscular fatigue in high performance athletes

    With improving professionalism of sports around the world, the volume and frequency of training required for competitive performances at the elite level has increased concurrently. With this amplification in training load comes an increased need to closely monitor the associated fatigue responses, …

    edithcowan Repository record for Monitoring neuromuscular fatigue in high performance athletes (opens in a new tab)

  8. Development and application of an eccentric force-velocity profile in rugby union athletes

    … trained rugby union athletes. Force plates and a linear position transducer captured force-time-displacement data across six loading conditions, separated by at least seven days. Eccentric peak force demonstrated good intraclass correlation coefficient (≥ 0.82) and typical error values (≤ 7.3%) …

    waikato-masters Repository record for Development and application of an eccentric force-velocity profile in rugby union athletes (opens in a new tab)