Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"line monitoring"”.

  1. On-line monitoring of water quality parameters

    … requirements for water quality. The need for on-line water quality monitoring and the alternative instrumental approaches to it are discussed, together with the philosophy of "easy care instrumentation" and water industry requirements for online analysers. A simple spectrophotometric FI system is …

    hull Repository record for On-line monitoring of water quality parameters (opens in a new tab)

  2. On-Line Monitoring, Control, and Reliability of Structural Dynamical Systems

    "Ideas for improving the efficiency of Monte Carlo simulation (MCS) is the subject of the final section. Determining the low failure probabilities of typical engineering systems is quite difficult without using millions of MCS realizations to characterize the probability distribution. Several links …

    uiuc Repository record for On-Line Monitoring, Control, and Reliability of Structural Dynamical Systems (opens in a new tab)

  3. An optimization of on-line monitoring of simple linear and polynomial quality functions

    … statistical performance of some of Phase II linear and polynomial profile monitoring techniques.</p> <p>For linear profiles the idea of variable sampling size (VSS) and variable</p> <p>sampling interval (VSI) have been extended from multivariate control charts to the profile monitoring

    wayne-thes Repository record for An optimization of on-line monitoring of simple linear and polynomial quality functions (opens in a new tab)

  4. Development and application of a new voltage stability index for on-line monitoring and shedding

    … for topology change detection suitable for online systems was proposed. Dynamic stability monitoring with PMU measurements was simulated in real-time on the well-known Kundur 10-bus system and the appropriate load shedding using the P-index was calculated. Compared to the another node-based …

    utc Repository record for Development and application of a new voltage stability index for on-line monitoring and shedding (opens in a new tab)

  5. Laser weld pool optical diagnostics: Topography and visualization used for surface contour analysis and process monitoring

    … areas of laser welding: visualization and on-line monitoring. Visualization of the pool has been greatly improved by illumination with both diffused and focused argon laser light. On-line measurement of the weld pool surface dimensions, detection of piece mismatch, and indication of non-fusion …

    uiuc Repository record for Laser weld pool optical diagnostics: Topography and visualization used for surface contour analysis and process monitoring (opens in a new tab)

  6. Process potentiometric sequential injection titrations

    … computerised, inexpensive and suitable for on-line monitoring.

    pretoria Repository record for Process potentiometric sequential injection titrations (opens in a new tab)

  7. A Hierarchical Filtering-Based Monitoring Architecture for Large-scale Distributed Systems

    <p>On-line monitoring is essential for observing and improving the reliability and performance of large-scale distributed (LSD) systems. In an LSD environment, large numbers of events are generated by system components during their execution and interaction with external objects (e.g. users or …

    odu Repository record for A Hierarchical Filtering-Based Monitoring Architecture for Large-scale Distributed Systems (opens in a new tab)

  8. Mullite Membrane Reference Electrode Evaluation and Application for Ni-Cr Corrosion Behavior in High Temperature Chloride Salts

    … membrane that is then applied to develop an on-line monitoring system of Ni-Cr alloy corrosion in chloride salt. A mullite tube used as the membrane of a Ni(II)/Ni reference electrode in molten MgCl2-NaCl-KCl is studied. The performance of two different membrane thicknesses (1.325mm and 0.255mm) …

    vt Repository record for Mullite Membrane Reference Electrode Evaluation and Application for Ni-Cr Corrosion Behavior in High Temperature Chloride Salts (opens in a new tab)

  9. Upflow anaerobic sludge blanket reactors for treatment of wastewater from the brewery industry

    … be used to develop and validate a predictive monitoring and controls solution to improve digester performance. The research project involved the design, construction, and instrumentation of lab-scale anaerobic digestion reactors to be used for the treatment of brewery wastewater. Useful …

    mit Repository record for Upflow anaerobic sludge blanket reactors for treatment of wastewater from the brewery industry (opens in a new tab)

  10. Applications of optical fiber sensors with thick metal coatings

    … however, in many applications, on-line monitoring of sensor elements is not required and the periodical addressing of sensor elements is acceptable. Commercially available fiber optic strain sensor systems are now available which support periodical sensor addressing by providing …

    vt Repository record for Applications of optical fiber sensors with thick metal coatings (opens in a new tab)

  11. Characterising water treatment works performance using fluorescence spectroscopy

    … with potential for incorporation into on-line monitoring systems, mean that fluorescence spectroscopy offers distinct advantages over other THM precursors characterisation techniques.

    birmingham Repository record for Characterising water treatment works performance using fluorescence spectroscopy (opens in a new tab)

  12. Trainable Pre-Filtering for Deep Neural Networks and Applications

    … and orthogonal transforms—into the learning pipeline, introducing explicit inductive bias while preserving end-to-end optimization. The proposed approach is validated across multiple real-world applications, including infrared air-leak identification, adversarially robust image classification, …

    uic

  13. Development of In Situ Monitoring and Data-Driven Modeling for Complex Systems: Case Study on Simulant Mixtures of Nuclear Waste

    … spectroscopy, is demonstrated for Real-Time In-Line Monitoring (RTIM) of simulated nuclear waste. In-situ monitoring will facilitate the continuous operation of the waste treatment facility and help reduce employee exposure to hazardous working conditions. The work in this thesis bridges the gap …

    gatech Repository record for Development of In Situ Monitoring and Data-Driven Modeling for Complex Systems: Case Study on Simulant Mixtures of Nuclear Waste (opens in a new tab)

  14. Double-frequency stator core vibration in large two-pole turbogenerators

    … to provide predictions suitable for an on-line monitoring scheme.<br/><br/>Electromagnetic forces at the stator bofe are represented as tooth-tip forces formed from the integral of Maxwell stress over a slot pitch. Conversion to core-back vibration is by means of transfer coefficients …

    soton Repository record for Double-frequency stator core vibration in large two-pole turbogenerators (opens in a new tab)

  15. Expert systems in A.C. induction motor fault diagnosis.

    … reliable techniques for non-invasive, on-line monitoring and fault diagnosis of large induction motors. Human knowledge and experience has to be used in conjunction with these techniques in order to circumvent the problem of unavailable or uncertain data and to make judgement on the degree …

    rgu Repository record for Expert systems in A.C. induction motor fault diagnosis. (opens in a new tab)

  16. A Raman Spectroscopic Study of Solid Dispersions and Co-crystals During the Pharmaceutical Hot melt Extrusion Process

    … reduction in production time with use of in-line, at-line and on-line measurements, yield improvement and energy and cost reductions. Hot Melt Extrusion process (HME) used in the present work is proving increasingly popular in industry for its continuous and green processing which is …

    bradford Repository record for A Raman Spectroscopic Study of Solid Dispersions and Co-crystals During the Pharmaceutical Hot melt Extrusion Process (opens in a new tab)

  17. Development of a video-based slurry sensor for on-line ash analysis

    … been limited by the lack of adequate on-line ash sensors. Several nuclear based analyzers are available, yet none have seen widespread acceptance by the coal industry. This is due largely to their high cost, the influences of seam type and pyrite content on accuracy, and the inconvenience …

    vt Repository record for Development of a video-based slurry sensor for on-line ash analysis (opens in a new tab)

  18. Enhancing Micro Free Flow Electrophoresis: Detection, Application, And Fabrication

    … sample purification, and continuous on-line monitoring. This work focuses on improving the sensitivity of laser induced fluorescence (LIF) detection via modifying the laser alignment, exploring new device designs for rapid on-line buffer exchange, and developing a novel fabrication …

    umn Repository record for Enhancing Micro Free Flow Electrophoresis: Detection, Application, And Fabrication (opens in a new tab)

  19. Reel-to-reel Characterization towards Feedback Control in Manufacturing Long REBCO High-Temperature Superconducting Tapes

    … REBCO tapes. This dissertation focuses on off-line and in-line characterization techniques for assessing the quality of long REBCO tapes. A reel-to-reel magnetization measurement method has been implemented for profiling the off-line critical current density of High-Temperature Superconducting …

    houston Repository record for Reel-to-reel Characterization towards Feedback Control in Manufacturing Long REBCO High-Temperature Superconducting Tapes (opens in a new tab)

  20. Acoustic sensing of renal stone fragmentation in extracorporeal shockwave lithotripsy

    … of emissions recorded in vivo to produce an on-line monitoring system. This trial was followed by other two trials that compared the output of the on-line acoustic system against the ‘gold standard’ X-Ray assessment of treatments outcomes. The former of these two trials involved 30 patients, and …

    soton Repository record for Acoustic sensing of renal stone fragmentation in extracorporeal shockwave lithotripsy (opens in a new tab)

Page 1 of 2