Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"laser alignment system"”.

  1. The laser alignment system for the CMS silicon microstrip tracker

    … with aprecision of a few hundred micron. The laser alignment system presented here has been designed for this purpose. Its goal is to measure the deformations of the mechanical support structure of the tracker with a precision better than 100 micron. The alignment system uses laser beams with …

    aachen Repository record for The laser alignment system for the CMS silicon microstrip tracker (opens in a new tab)

  2. Construction and calibration of the laser alignment system for the CMS tracker

    … (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 meter and a length of 5.4 meter representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 square …

    aachen Repository record for Construction and calibration of the laser alignment system for the CMS tracker (opens in a new tab)

  3. Expected measurement of the Z production rate with the CMS detector and simulation of the Tracker Laser Alignment System

    … are foreseen for 2009. The Compact Muon System (CMS) detector will measure the particles created in the hadron collisions and can confirm the Standard Model by establishing the existence of the Higgs boson, but also search for new phenomena. In order to provide a robust and precise track …

    aachen Repository record for Expected measurement of the Z production rate with the CMS detector and simulation of the Tracker Laser Alignment System (opens in a new tab)

  4. Deformation studies on CMS endcap modules and misalignment studies on the CMS tracker

    … the endcap of the CMS tracker * The effect of misalignment of the tracker support structure on the performance of the CMS tracker 0.1 Deformation Measurements In chapter two the possible deformations of the TEC modules under temperature changes have been investigated. A test setup to measure …

    aachen Repository record for Deformation studies on CMS endcap modules and misalignment studies on the CMS tracker (opens in a new tab)

  5. Integration of the end cap TEC+ of the CMS silicon strip tracker

    … particle physics whose inner tracking system is exclusively instrumented with silicon detector modules. This tracker comprises 15148 silicon strip modules enclosing the interaction point in 10–12 layers. The 1. Physikalisches Institut B of RWTH Aachen was deeply involved in the …

    aachen Repository record for Integration of the end cap TEC+ of the CMS silicon strip tracker (opens in a new tab)