Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 410 for “"inductively coupled plasma"”.

  1. Simulation of Magnetically Confined Inductively Coupled Plasma

    … presented to address the need for high density inductively coupled plasmas with enhanced properties and a more uniform and consistent distribution, suitable for large-area material processing. Fluid model simulations of 3D argon inductively coupled plasma (ICP) were performed in COMSOL for the …

    sdstate Repository record for Simulation of Magnetically Confined Inductively Coupled Plasma (opens in a new tab)

  2. FLUORESCENCE STUDIES IN THE INDUCTIVELY COUPLED PLASMA

    … searches were used to optimise several plasma parameters, i.e. forward power; viewing height ALC; plasma, nebuliser and auxiliary gas flow rates. Once the optimum conditions had been determined, calibration curves were plotted for each of the elements studied (Ba, Li, Mg and Na). The …

    plymouth Repository record for FLUORESCENCE STUDIES IN THE INDUCTIVELY COUPLED PLASMA (opens in a new tab)

  3. Inductively Coupled Plasma Etching of III-N Semiconductors

    … of an in-house designed and constructed inductively coupled plasma (ICP) system for integrated studies pertaining to the etching rates and etching selectivity among AlN, GaN, and Al(x)Ga(1-x)N. An (ICP) system was chosen because of its high plasma density and low cost relative to other …

    ncsu Repository record for Inductively Coupled Plasma Etching of III-N Semiconductors (opens in a new tab)

  4. Solid sample introduction in inductively coupled plasma emission spectrometry.

    … made in the area of solid sample introduction in Inductively Coupled Plasma Emission Spectrometry (ICP-ES). As an alternative to solution nebulisation two methods of introducing samples to the ICP are investigated. The first of these uses the direct insertion probe technique first described by …

    sheffield-hallam Repository record for Solid sample introduction in inductively coupled plasma emission spectrometry. (opens in a new tab)

  5. Trace Evidence Analysis of Forensic Samples Using Inductively Coupled Plasma

    … techniques for multi-elemental trace analysis is inductively coupled plasma (ICP) spectrometry; yet, it is seldom used for forensic analysis. In this thesis, four different forensic applications will be explored using ICP spectrometry involving four different types of sample: human head hair, …

    queens Repository record for Trace Evidence Analysis of Forensic Samples Using Inductively Coupled Plasma (opens in a new tab)

  6. Laser ablation for sample introduction in inductively coupled plasma spectrometry.

    … as a means of sample introduction for the Inductively Coupled Plasma (ICP). This involved the configuration of an ICP spectrometer, a laser and a novel laser ablation chamber. The latter offered the facility of electrothermally heating samples before or during laser ablation.Several …

    sheffield-hallam Repository record for Laser ablation for sample introduction in inductively coupled plasma spectrometry. (opens in a new tab)

  7. Production of barium cerate films using an inductively coupled plasma reactor

    Includes bibliographical references (pages 86-89).

    colo-mines Repository record for Production of barium cerate films using an inductively coupled plasma reactor (opens in a new tab)

  8. Field sampling and microcolumn preconcentration techniques in inductively coupled plasma spectrometry.

    … are subsequently eluted and quantified by inductively coupled plasma-emission spectrometry (ICP-ES).Initial studies focus on trace analytes in caesium iodide, however a selection of the alkali metal salts, lithium nitrate, potassium bromide, sodium fluoride and sodium chloride, are …

    sheffield-hallam Repository record for Field sampling and microcolumn preconcentration techniques in inductively coupled plasma spectrometry. (opens in a new tab)

  9. Production of barium cerate films using an inductively coupled plasma reactor

    Includes bibliographical references (pages 86-89).

    colo-mines Repository record for Production of barium cerate films using an inductively coupled plasma reactor (opens in a new tab)

  10. Modeling of non-equilibrium plasmas in an inductively coupled plasma facility

    … of ionized gas flows inside the torch of an inductively coupled plasma facility in the von Karman Institute for Fluid Dynamics. The main purpose of this work is the parametric investigation of thermo-chemical non-equilibrium effects on the plasma jet at different operating pressures ranging …

    uiuc Repository record for Modeling of non-equilibrium plasmas in an inductively coupled plasma facility (opens in a new tab)

  11. Slurry, Solution and Speciation Analysis By Inductively Coupled Plasma Atomic Emission Spectrometry

    Inductively coupled plasma atomic emission spectrometry has been investigated for solution, slurry and speciation analysis. It has been shown that it is possible to optimise a simultaneous multielement analysis for slurry and solution samples using solid state detection and optimisation algorithms. …

    plymouth Repository record for Slurry, Solution and Speciation Analysis By Inductively Coupled Plasma Atomic Emission Spectrometry (opens in a new tab)

  12. Computational modeling of test articles in the PlasmatronX inductively coupled plasma facility

    Submission published under a 24 month embargo labeled 'Closed Access', the embargo will last until 2027-08-01

    uiuc Repository record for Computational modeling of test articles in the PlasmatronX inductively coupled plasma facility (opens in a new tab)

  13. OPTIMISATION OF THE INDUCTIVELY-COUPLED PLASMA FOR THE ANALYSIS OF SOLUTIONS AND SLURRIES

    The application of inductively-coupled plasma (ICP) spectrometry for the analysis of solutions and slurries is reviewed. The critical parameters which affect analytical performance are identified and methods for the optimisation of the ICP for such applications demonstrated. Particle size of the …

    plymouth Repository record for OPTIMISATION OF THE INDUCTIVELY-COUPLED PLASMA FOR THE ANALYSIS OF SOLUTIONS AND SLURRIES (opens in a new tab)

  14. DEVELOPMENT OF A LOW PRESSURE-INDUCTIVELY COUPLED PLASMA-ION SOURCE FOR MASS SPECTROMETRY

    A low pressure-inductively coupled plasma (LP-ICP) ion source has been investigated for the production of atomic and molecular ions for mass spectrometry (MS). A dedicated LPICP- MS was constructed, by modifying a Hewlett Packard mass selective detector, to detect ions from the LP-ICP. The ion …

    plymouth Repository record for DEVELOPMENT OF A LOW PRESSURE-INDUCTIVELY COUPLED PLASMA-ION SOURCE FOR MASS SPECTROMETRY (opens in a new tab)

  15. Elemental speciation and miniaturised sample introduction studies for inductively coupled plasma mass spectrometry

    … the development of sample introduction for inductively coupled plasma mass spectrometry (ICPMS). The ultimate aim is to develop methods for conducting rapid speciation analysis. This is approached in two ways; firstly using liquid chromatography (LC) employing a column with a monolithic …

    hull Repository record for Elemental speciation and miniaturised sample introduction studies for inductively coupled plasma mass spectrometry (opens in a new tab)

  16. Interfacing High Performance Liquid Chromatography with Inductively Coupled Plasma Mass Spectrometry for Speciation Studies

    … performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for the speciation of organometallic compounds has been developed and utilised for a number of diverse applications. Desolvation of the sample prior to reaching the plasma is shown to facilitate …

    plymouth Repository record for Interfacing High Performance Liquid Chromatography with Inductively Coupled Plasma Mass Spectrometry for Speciation Studies (opens in a new tab)

  17. Separation, preconcentration and determination of rare earth elements by inductively coupled plasma emission spectroscopy

    … program was established using an IL 200 Inductively Coupled Plasma, (ICP), spectrometer for the determination of the REE in various matrices, taking into consideration both matrix and spectral interferences, which were found to be severe in some cases. Dissolution of the sample, (0.4-1.0 …

    cape-town Repository record for Separation, preconcentration and determination of rare earth elements by inductively coupled plasma emission spectroscopy (opens in a new tab)

Page 1 of 21