Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"heat flux microsensor"”.

  1. Feedforward temperature control using a heat flux microsensor

    The concept of using heat flux measurements to provide the input for a feedforward temperature control loop is investigated. The feedforward loop is added to proportional and integral feedback control to increase the speed of the response to a disturbance. Comparison is made between the feedback …

    vt Repository record for Feedforward temperature control using a heat flux microsensor (opens in a new tab)

  2. Development and calibration of a heat flux microsensor

    … and calibration of a new type of layered heat flux gage is described. Using thin-film microfabrication techniques the gage design is able to combine many of the desirable characteristics of other previous gage designs to produce a gage that has a very small size, high frequency response, …

    vt Repository record for Development and calibration of a heat flux microsensor (opens in a new tab)

  3. Evaluation of a Heat Flux Microsensor in a Transonic Turbine Cascade

    The effects of using an insert Heat Flux Microsensor (HFM) versus an HFM deposited directly on a turbine blade to measure heat flux in a transonic cascade are investigated. The HFM is a thin-film sensor, 6.35 mm (0.250") in diameter (for an insert gage, including the housing) which measures heat

    vt Repository record for Evaluation of a Heat Flux Microsensor in a Transonic Turbine Cascade (opens in a new tab)

  4. Measurements of thermal properties and blood perfusion using the heat flux microsensor

    A thin-film heat flux sensor was used in two transient conduction applications. First it was used in a device for simultaneously determining the thermal conductivity, κ, and the thermal diffusivity, α, of solid materials. The device was heated and then touched to metal samples at room temperature. …

    vt Repository record for Measurements of thermal properties and blood perfusion using the heat flux microsensor (opens in a new tab)

  5. Simultaneous direct measurements of skin friction and heat flux in a supersonic flow

    A new gage which can measure skin friction and heat flux simultaneously was designed, constructed, and tested. This gage is the combination of a non-nulling type skin friction balance and a heat flux microsensor. By mounting the heat flux microsensor directly on the surface of the floating element …

    vt Repository record for Simultaneous direct measurements of skin friction and heat flux in a supersonic flow (opens in a new tab)

  6. Time-resolved heat flux measurements of the turbulent junction vortex system

    A rapid-response thin-film heat flux sensor was used to measure time-resolved unsteady heat flux in a complex junction vortex flow. This sensor, called the Heat Flux Microsensor, was used with a hot-wire anemometer to make simultaneous measurements of velocity and surface heat flux. The results …

    vt Repository record for Time-resolved heat flux measurements of the turbulent junction vortex system (opens in a new tab)

  7. The simultaneous measurement of time-resolved surface heat flux and freestream turbulence at a stagnation point

    Two rapid-response thin-film heat flux gage systems have been used to measure time-resolved unsteady heat transfer signals. The Heat Flux Microsensor is a passive gage which measures the temperature difference across a thin thermal resistance. The second sensor, an actively powered gage operated by …

    vt Repository record for The simultaneous measurement of time-resolved surface heat flux and freestream turbulence at a stagnation point (opens in a new tab)

  8. An experimental investigation of turbine blade tip heat transfer and tip gap flows in the supersonic regime

    Gas turbine blade tip heat transfer and tip gap flow phenomena has been explored experimentally in a stationary cascade for blade exit Mach numbers = 1.2 to 1.4. Experimental results were found to agree well with qualitative predictions performed at GE Aircraft Engines. The pressure distribution in …

    vt Repository record for An experimental investigation of turbine blade tip heat transfer and tip gap flows in the supersonic regime (opens in a new tab)

  9. Design and Calibration of a Novel High Temperature Heat Flux Sensor

    Heat flux gages are important in applications where measurement of the transfer of energy is more important than measurement of the temperature itself. There is a need for a heat flux sensor that can perform reliably for long periods of time in high temperature and high heat flux environment. The …

    vt Repository record for Design and Calibration of a Novel High Temperature Heat Flux Sensor (opens in a new tab)

  10. A frequency domain analysis of surface heat transfer/free-stream turbulence interactions in a transonic turbine cascade

    The relationship of time-resolved surface heat flux to the turbulent free-stream flow over a turbine blade is investigated. Measurements are made in a transonic linear cascade with a modem high pressure turbine blade profile. Time-resolved direct heat transfer measurements are made with Heat Flux

    vt Repository record for A frequency domain analysis of surface heat transfer/free-stream turbulence interactions in a transonic turbine cascade (opens in a new tab)