The effect of acute fatigue on reactive strength index in modern dancers
… female, 4 male) participated in this study. Two force plates were utilized to record the force-time data during drop jumps (DJ) before and after an acute, fatiguing protocol. Dancers performed a 5-10 minute self-selected warm up followed by 3-5 practice trials of DJs onto the force plates. Three …
-
Frequency Modulated Continuous Wave Radar Based Fall Risk Monitoring System
… with ground-truth contactbased lab sensors like force plates and motion capture systems, establishing a foundation for accurate balance assessments in home settings. In our cross-sectional analysis, participants performed the one-legged stand test (OLST) with simultaneous data collection from …
-
Development and clinical bench testing of a Matlab based, user friendly, deployable software application for automatic batch processing of fully instrumented three-dimensional human movement biomechanics data
… capture systems in conjunction with data from force plates. The information is processed with kinematic and kinetic models which output vast amounts of data. For analysis, gait data is separated into individual cycles and normalized from 1-100% where certain events are expected to occur at …
-
The Effects Of Age And Distraction On Interlimb Synchronization Of The Center Of Pressure
… performed quiet standing trials on separate force plates under eyes-open and eyes-closed conditions, with and without cognitive distraction (counting by ones, backward by sevens). Interlimb synchrony was assessed using cross-correlation (CCF) of center of pressure (COP) movements, while root …
-
Can changing running shoes immediately reduce the risk of tibial stress fractures?
… The test protocol utilized 3D motion capture, force plates, and EMG. The findings of the current study suggest that strike pattern and foot alignment rather than shoes are the determining factors in eliminating risk factors for TSF. Future works should involve fatigue studies and gait …
-
Use of Isometric Mid-Thigh Pull to Determine Asymmetrical Strength Differences in NCAA D-I Athletes.
… 2 maximal effort isometric pulls over two force plates sampling at 1000 Hz each. Peak force was scaled for body weight, and rate of force development was examined from 0-200ms. Results of the study show subjects' produced significantly greater scaled force with the left leg as compared to …
-
NEUROMUSCULAR PERFORMANCE ASSESSMENTS AND MONITORING IN COLLEGIATE NCAA DIVISION I BASKETBALL ATHLETES: AN ADOPTION OF THE APPLIED RESEARCH MODEL FOR THE SPORT SCIENCES
… in decision-making for respective stakeholders. Force plates allow for quantification of vertical jump tasks reflective of stretch-shortening cycle (SSC) efficiency and are frequently implemented to assess neuromuscular status in athlete populations. However, evidence is limited as to which …
-
Changes in Balance with Brain Inflammation: Sensitivity in Dual Motor Mechanisms
… assessments including quiet stance trials on force plates. COPc and COPv signals were analyzed for average velocity, root mean square of distance, and 95% range. Concussed athletes' data were compared to a baseline population. COPv exhibited greater sensitivity to concussion-induced balance …
-
An experimental comparison of hitting mechanics in softball
… of the bat to determine bat velocity, while two force plates measured the transfer of weight as nine softball players swung a bat twenty times- ten times with a ball on the tee and ten times with a ball off of the tee. Although it was found that the two hitting models had statistically different …
-
An Exploratory Biomechanical Analysis of the Side-to-Side Swing Patterns of Three Skilled Switch Hitters
… switch hitters participated. Subjects stood on force plates and hit baseballs off a tee while their swings were recorded with a three-dimensional optical motion capture system. Each subject performed twenty total swings, ten from the right and ten from the left. The swings were digitally …
-
The Use of Motion Analysis Technology as an Alternative Means of Assessing Spinal Deformity in Patients with Adolescent Idiopathic Scoliosis
… radiation. Using retro-reflective markers and force plates, it is possible to determine asymmetries in the frontal and transverse plane, to calculate the balance of the spine, to replicate common radiographic measures, and to determine the kinematic profiles of the spine for each patient.</p> …
-
THE ACUTE AND CHRONIC EFFECTS OF HIGHLY CUSHIONED SHOES ON LOADING CHARACTERISTICS IN RECREATIONAL RUNNERS
… HCS intervention on running-related impact forces in adult recreational runners. We hypothesized HCS would result in altered force attenuation compared to standard cushioned shoes (SCS) at baseline. After 4-weeks, we speculated differences would not be attenuated. Twenty-nine healthy runners …
-
Assessing Symmetry in Landing Mechanics During Single-Leg and Bilateral Tasks in Healthy Recreational Athletes
… motion analysis system (240Hz) and 2 embedded force plates (1920Hz). Limb symmetry indices (LSIs) were calculated for each variable and compared between subject groups, tasks, and sexes with Wilcoxon Signed Rank tests (p<0.05). RESULTS: Control subjects exhibited asymmetry in hop distance …
-
Balance Performance Measurment in a Phase Shifted Feedback Environment
… popular balance training software which utilizes force plates to measure center of pressure and display the results in a stimulus and response study. Ten healthy young-adult subjects with no known balance deficits were recruited to participate in this study. Subjects were asked to stand on a pair …
-
Effects of Quadriceps Fatigue on the Outcomes of Slips and Falls
… a three-dimensional video analysis system and force plates during both sessions. The gait parameters important in assessing slip severity were compared for the two different sessions to evaluate the effects of fatigue. A repeated measure one-way analysis of variance (ANOVA) and multivariate …
-
Characterising individual running gait: A field based, scalable approach
… have come by way of instrumented treadmills and force plates, with the advent of multiple sequenced force plates providing unique insights in recent years. While these studies have provided invaluable foundational knowledge, the insights cannot specifically be implemented in the field due to the …
-
Utilizing machine learning techniques in estimating ankle prosthesis power output using wearable IMU sensors
… using invasive motion capture systems along with force plates to capture the exerted power on the ground during stance phase. When clinicians are fitting prosthesis on to amputees it can be hard to produce real data that could be used to assist with the fitting and prosthesis choosing process. …
-
The direct effects of variations in AFO stiffness on the kinematics and kinetics of gait
… solid AFO made of copolymer polypropylene & reinforced with carbon fibre inserts. 2. Posterior leaf spring (PLS) made of copolymer polypropylene. 3. SWIFT Cast with a six-layer Scotch back slab. 4. SWIFT Cast with an eight-layer Scotch back slab. The Instron test machine and a custom-made …
-
The effects of using a lateral wedge insole on knee loading during ascending and descending stairs
… using a motion capture system (QTM ) andtwo force plates (AMTI force platform stairway). Repeated measures ANOVA andFriedman's ANOVA were used for statistical analysis.Results: During stairs ascent and descent, a lateral wedge insole significantly (p<0.05)reduced the EKAM's 1 st peak in early …
-
An investigation into the relationship between knee axis alignment and swing phase whip during trans-femoral amputee gait
… the current study. Infra-red camera system and force plates were used tocollect kinematic and kinetic data of the gait of the amputee participant under fourdifferent alignment conditions. The effects of changing prosthetic knee axis alignmentin the coronal and transverse plane on lateral whip …