Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 43 for “"flow meter"”.

  1. Design of a Resistance-Based High Temperature Liquid Metal Flow Meter

    Flow rate is a parameter that is vital to measure in high temperature pumped liquid metal systems, yet traditional flow meters are unable to perform at these extreme conditions. As a part of the Atomic Simulation & Energy (ASE) Research Group here at MIT, this research seeks to develop a flow meter

    mit Repository record for Design of a Resistance-Based High Temperature Liquid Metal Flow Meter (opens in a new tab)

  2. The feasibility of micromachined dynamic resonant beam coriolis true mass flow meter

    … such as pressure sensors and accelerometers. MEMS flow sensing has emerged as a field of interest in microfluidics, with a variety of sensing methods being miniaturized, such as thermal anemometry, ultrasonic sensing and flow measurement based on the Coriolis effect. Coriolis sensing …

    njit Repository record for The feasibility of micromachined dynamic resonant beam coriolis true mass flow meter (opens in a new tab)

  3. Investigation of performance of an ultrasonic flow meter for potential molten salt reactor applications

    … what the design, there is a need to measure the flow rate of the salt during operation. The nature of the salt greatly complicates the use of a flow meter that must be submerged in the salt. Ultrasonic flow meters have been used for decades with a variety of fluids. These clamp on the outside of …

    mit Repository record for Investigation of performance of an ultrasonic flow meter for potential molten salt reactor applications (opens in a new tab)

  4. Measurement of total hydrocarbon emissions with MEMS using a portable FID and a novel exhaust flow meter

    … Model 3030PM hydrocarbon analyzer and McCrometer's V-Cone flow meter. The Signal Model 3030PM analyzer uses a heated flame ionizing detection scheme to measure hydrocarbons. The V-Cone is an obstructive, differential pressure flow meter that reshapes the flow profile, therefore conditioning …

    wvu Repository record for Measurement of total hydrocarbon emissions with MEMS using a portable FID and a novel exhaust flow meter (opens in a new tab)

  5. A virtual flow meter to develop velocity-index ratings and evaluate the effect of flow disturbances on these ratings

    Stream flow records are typically estimated with the use of empirical rating curves. The conventional rating method relates stage to discharge, however at sites prone to flow reversals, changes in stream bed roughness, backwater, and tidal effects, a stage-discharge rating is not unique and a …

    uiuc Repository record for A virtual flow meter to develop velocity-index ratings and evaluate the effect of flow disturbances on these ratings (opens in a new tab)

  6. Analysis of vortex shedding in a various body shapes

    … shape of bluff body that can be used for vortex flow meter applications. Numerical simulations of bluff body shapes such as circular, rectangular and equilateral triangular have been carried out to understand the phenomenon of vortex shedding. The simulation applied

    uthm Repository record for Analysis of vortex shedding in a various body shapes (opens in a new tab)

  7. Evaluation and visualization of refrigerant two-phase flow in distributor

    This study aims at understanding flow distribution exiting thermostatic expansion valve and through distributor. It is well known that when two-phase flow goes through separation devices such as distributors and headers, mal-distribution is unavoidable due to different properties of liquid and …

    uiuc Repository record for Evaluation and visualization of refrigerant two-phase flow in distributor (opens in a new tab)

  8. Left Ventricle Assist Device

    … the cardiac cycle and capturing pressure and flow meter readings. The research focused on developing and testing a mock circulatory loop that accurately captures pressure and flow meter readings. The team experimented with various silicone elastomers and a urethane-based material, ClearFlex …

    vt Repository record for Left Ventricle Assist Device (opens in a new tab)

  9. Thermal Conductivity of foamed concrete

    … is presented. Experiments were done using a heat flow meter according to ASTM C 518-02. The experimental results show that thermal conductivity decreases with increasing foam content, water-cement ratio and increasing polymer content. Numerical analysis using FLUENT software shows that thermal …

    nus Repository record for Thermal Conductivity of foamed concrete (opens in a new tab)

  10. Bayesian models for screening and diagnosis of pulmonary disease

    … stethoscope, an augmented reality peak flow meter, and an electronic questionnaire. Previously, logistic regression has been used for modeling pulmonary disease.

    mit Repository record for Bayesian models for screening and diagnosis of pulmonary disease (opens in a new tab)

  11. Design and validation of mobile kit and machine learning algorithms for pulmonary disease screening and diagnosis

    … stethoscope, an augmented reality peak flow meter, and an electronic questionnaire. Using this kit, we collected data from patients who visited the Chest Research Foundation, a pulmonary clinic in Pune, India. Using the data collected from these patients, we pursued several of avenues of …

    mit Repository record for Design and validation of mobile kit and machine learning algorithms for pulmonary disease screening and diagnosis (opens in a new tab)

  12. Refrigerant charge reduction in small commercial refrigeration systems

    … of them, as well as pressure transducers, a mass flow meter, and thermocouples. Charge optimization and charge distribution experiments were conducted. The condenser is found to be the component that retains the most charge. The system was modeled using Engineering Equation Solver (EES) for …

    uiuc Repository record for Refrigerant charge reduction in small commercial refrigeration systems (opens in a new tab)

  13. Design and Characterization of a High pressure Flow Loop for Heat Transfer Experiments of Supercritical Carbon Dioxide

    … crucial phenomenon, a state-of-the-art closed flow loop was developed. This setup enabled convective heat transfer experiments of sCO2 under diverse boundary conditions and test section geometries. Key components of the loop include the test section, constant temperature bath, pump, flow meter, …

    embry-riddle Repository record for Design and Characterization of a High pressure Flow Loop for Heat Transfer Experiments of Supercritical Carbon Dioxide (opens in a new tab)

  14. Modeling and Applications of Thermoelectric Generators

    … harvested power to different inputs and TEG parameters is detailed. In the second part of the dissertation, we integrate a thermoelectric generator with an organic storage device. The performance of the integrated system for different values of load resistances and temperature gradients is …

    vt Repository record for Modeling and Applications of Thermoelectric Generators (opens in a new tab)

  15. Modeling the Arterial System to Improve Ultrasound Measurements of Hemodynamic Parameters

    One of the most crucial parameters for monitoring Cardiovascular disease (CVD) risk is one’s Arterial Blood Pressure (ABP). Clinicians use a radial arterial catheter to measure ABP in an intensive care unit (ICU). Although this method is considered the gold standard, its invasive nature makes it …

    mit Repository record for Modeling the Arterial System to Improve Ultrasound Measurements of Hemodynamic Parameters (opens in a new tab)

  16. An Unsteady State Tracer Dilution Method for Characterizing Water Contributing Fractures in Crystalline Bedrock Wells

    … of methods including downhole geophysics, flow meters, and straddle packers. These methods are expensive, time consuming, and can be logistically difficult to implement. This study demonstrates an unsteady state tracer method as a cost effective alternative for gathering fracture …

    uconn-diss Repository record for An Unsteady State Tracer Dilution Method for Characterizing Water Contributing Fractures in Crystalline Bedrock Wells (opens in a new tab)

  17. Characterization and Modeling of the Thermal Properties of Photopolymers for Material Jetting Processes

    … TangoBlackPlus, and Grey60) by using the heat flow meter method. The resulting thermal conductivities are then applied in finite element analysis (FEA) simulations to model the thermal distribution of heated PolyJet parts. Two FEA models of one-dimensional conduction in PolyJet parts are …

    vt Repository record for Characterization and Modeling of the Thermal Properties of Photopolymers for Material Jetting Processes (opens in a new tab)

  18. Cavitation and Bubble Formation in Water Distribution Systems

    … visual observation of bubbles, an inline turbidimeter, an ultrasonic flow meter, and an inline total dissolved gas probe were used to track the phenomenon. All four measurements confirmed that gaseous cavitation was occurring within the experimental distribution system, even at pressures up to 40 …

    vt Repository record for Cavitation and Bubble Formation in Water Distribution Systems (opens in a new tab)

  19. Modeling and Experimental Investigation of Parabolic Trough Solar Collector

    … a storage tank, a heat exchanger (radiator), and flow meter. Thermocouples were used to measure the inlet and outlet temperature of PTSC (the second trough). Water is used as a working fluid. After data were recorded, thermal performance analysis was performed. The results indicate that a maximum …

    embry-riddle Repository record for Modeling and Experimental Investigation of Parabolic Trough Solar Collector (opens in a new tab)

Page 1 of 3